Layered Carbon Nanotube-Polyelectrolyte Electrodes Outperform Traditional Neural Interface Materials

被引:99
作者
Jan, Edward [1 ]
Hendricks, Jeffrey L. [2 ]
Husaini, Vincent [1 ]
Richardson-Burns, Sarah M. [3 ]
Sereno, Andrew [3 ]
Martin, David C. [2 ,3 ]
Kotov, Nicholas A. [1 ,2 ,3 ]
机构
[1] Univ Michigan, Dept Chem Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Mat Sci & Engn, Ann Arbor, MI 48109 USA
关键词
IRIDIUM OXIDE; CONDUCTING-POLYMER; FILMS; POLY(3,4-ETHYLENEDIOXYTHIOPHENE); STIMULATION; DESIGN; POLYPYRROLE; CELLS;
D O I
10.1021/nl902187z
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The safety, function, and longevity of implantable neuroprosthetic and cardiostimulating electrodes depend heavily on the electrical properties of the electrode-tissue interface, which in many cases requires substantial improvement, While different variations of carbon nanotube materials have been shown to be suitable for neural excitation, it is critical to evaluate them versus other materials used for bioelectrical interfacing, which have not been done in any study performed so far despite strong interest to this area. In this study, we carried out this evaluation and found that composite multiwalled carbon nanotube-polyelectrolyte (MWNT-PE) multilayer electrodes substantially outperform in one way or the other state-of-the-art neural interface materials available today, namely activated electrochemically deposited iridium oxide (IrOx) and poly(3,4-ethylenedioxythiophene) (PEDOT). Our findings provide the concrete experimental proof to the much discussed possibility that carbon nanotube composites can serve as excellent new material for neural interfacing with a strong possibility to lead to a new generation of implantable electrodes.
引用
收藏
页码:4012 / 4018
页数:7
相关论文
共 49 条
[1]   Experimental and theoretical characterization of implantable neural microelectrodes modified with conducting polymer nanotubes [J].
Abidian, Mohammad Reza ;
Martin, David C. .
BIOMATERIALS, 2008, 29 (09) :1273-1283
[2]   Conducting-polymer nanotubes for controlled drug release [J].
Abidian, MR ;
Kim, DH ;
Martin, DC .
ADVANCED MATERIALS, 2006, 18 (04) :405-+
[3]   Biological glass fibers: Correlation between optical and structural properties [J].
Aizenberg, J ;
Sundar, VC ;
Yablon, AD ;
Weaver, JC ;
Chen, G .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (10) :3358-3363
[4]  
An KH, 2001, ADV MATER, V13, P497, DOI 10.1002/1521-4095(200104)13:7<497::AID-ADMA497>3.0.CO
[5]  
2-H
[6]  
CHUNSHENG D, 2006, NANOTECHNOLOGY, P5314
[7]   In vitro comparison of the charge-injection limits of activated iridium oxide (AIROF) and platinum-iridium microelectrodes [J].
Cogan, SF ;
Troyk, PR ;
Ehrlich, J ;
Plante, TD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (09) :1612-1614
[8]   Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation [J].
Cogan, SF ;
Guzelian, AA ;
Agnew, WF ;
Yuen, TGH ;
McCreery, DB .
JOURNAL OF NEUROSCIENCE METHODS, 2004, 137 (02) :141-150
[9]   Electrochemical deposition and characterization of poly(3,4-ethylenedioxythiophene) on neural microelectrode arrays [J].
Cui, XY ;
Martin, DC .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (1-2) :92-102
[10]   Poly (3,4-ethylenedioxythiophene) for chronic neural stimulation [J].
Cul, Xinyan Tracy ;
Zhou, David Daomin .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2007, 15 (04) :502-508