Arthopor 2 acetabular component with screw fixation in primary hip arthroplasty - A 7- to 9-year follow-up study

被引:12
作者
Dearborn, JT [1 ]
Murray, WR [1 ]
机构
[1] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA 94143 USA
关键词
hip arthroplasty; acetabular component; screw fixation; polyethylene wear;
D O I
10.1016/S0883-5403(98)90176-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The first 100 consecutive primary hip arthroplasties with the Arthopor 2 acetabular component (Joint Medical Products, Stamford, CT) with supplemental screw fixation performed by the senior author were prospectively studied. The mean patient age was 57 years. Seventy-seven cemented and 23 cementless stems were placed, with 32-mm femoral heads used in most of the patients. Eighty-six hips were reviewed at 7-8.8 years (mean, 7.8 years). The mean Harris hip score at final follow-up evaluation was 94 points. No cups have been revised, although 2 cups in patients with radiation osteonecrosis were loose radiographically. One patient underwent revision of a severely worn liner. Despite a relatively high mean linear wear rate of 0.27 mm/y (range, 0.13-0.57 mm/y), no radiographic evidence of pelvic osteolysis was seen. The Arthopor 2 cup performed well with respect to pelvic osteolysis, despite the presence of substantial polyethylene debris. The relatively high polyethylene wear rate is attributed in part to the younger patient population and the use of 32-mm femoral heads paired with thin polyethylene liners.
引用
收藏
页码:299 / 310
页数:12
相关论文
共 62 条
[1]  
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]  
[Anonymous], CLIN ORTHOPAEDICS
[3]  
*ASTM, 1993, 1993 ANN BOOK ASTM S, V13, P186
[4]  
Bankston A B, 1993, J Arthroplasty, V8, P315
[5]  
BANKSTON AB, 1995, CLIN ORTHOP RELAT R, P37
[6]   COMPLICATIONS RELATED TO MODULARITY OF TOTAL HIP COMPONENTS [J].
BARRACK, RL ;
BURKE, DW ;
COOK, SD ;
SKINNER, HB ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05) :688-692
[7]   THE EFFECT OF CONFORMITY AND PLASTIC THICKNESS ON CONTACT STRESSES IN METAL-BACKED PLASTIC IMPLANTS [J].
BARTEL, DL ;
BURSTEIN, AH ;
TODA, MD ;
EDWARDS, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (03) :193-199
[8]   CATASTROPHIC FAILURE OF THE POLYETHYLENE LINER OF UNCEMENTED ACETABULAR COMPONENTS [J].
BERRY, DJ ;
BARNES, CL ;
SCOTT, RD ;
CABANELA, ME ;
POSS, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (04) :575-578
[9]   DISSOCIATION OF ACETABULAR COMPONENTS AFTER TOTAL HIP-ARTHROPLASTY - REPORT OF 4 CASES [J].
BRIEN, WW ;
SALVATI, EA ;
WRIGHT, TM ;
NELSON, CL ;
HUNGERFORD, DS ;
GILLIAM, DL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (10) :1548-1550
[10]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632