CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: Results with an automated 20-gauge coaxial cutting needle

被引:150
作者
Laurent, F
Latrabe, V
Vergier, B
Montaudon, M
Vernejoux, JM
Dubrez, J
机构
[1] Univ Bordeaux 2, CHU Bordeaux, Hosp Haut Leveque, Dept Radiol, F-33604 Pessac, France
[2] Univ Bordeaux 2, Dept Pathol, Hosp Haut Leveque, F-33604 Pessac, France
[3] Univ Bordeaux 2, Dept Pneumol, Hosp Haut Leveque, F-33604 Pessac, France
[4] Univ Bordeaux 2, Dept Thorac Surg, Hosp Haut Leveque, F-33604 Pessac, France
关键词
biopsy; technology; computed tomography; guidance; interventional procedures; complications; lung biopsy; neoplasm; diagnosis;
D O I
10.1053/crad.1999.0368
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIMS: To evaluate the efficacy and the complication rate of CT-guided percutaneous lung biopsy of pulmonary nodules smaller than 20 mm in diameter using a 20-gauge coaxial automated biopsy device. MATERIAL AND METHODS: A prospective study was undertaken of 200 patients who underwent 202 consecutive biopsies of pulmonary nodules, performed with a single type of automated biopsy device. Sixty-seven biopsies of nodules smaller than 20 mm in diameter were performed in 66 patients (group A). One hundred and thirty-five biopsies of lesions of 20 mm or greater in size were performed in 134 patients (group B). Patient characteristics, lesion and procedure variables, the accuracy and complication rates were compared. RESULTS: In group A, the final diagnosis of the nodules was malignant in 47 and benign in 19 cases (prevalence of malignancy 71.2%). In group B, there were 111 malignant and 21 benign diagnoses (prevalence of malignancy 82.2%). In group A, the sensitivity and specificity for a diagnosis of malignancy were 89.5 and 100%, respectively (positive predictive value 100%, negative predictive value 76%). A specific diagnosis of benignity was obtained in nine out of 19 (47%) biopsies. The pneumothorax rate was 15% (10 patients) of which two (3%) required drainage. CT signs thought to reflect alveolar haemorrhage were noted in 28 (43%) and haemoptysis occurred in five patients (5.9%). In group B, the sensitivity and specificity for a diagnosis of malignancy were 95.5% and 100%, respectively (positive predictive value 100%, negative predictive value 82.7%). A specific diagnosis of benignity was made in 14 cases (58.3%). Complications included pneumothoraces in 22 cases (16.2%) requiring drainage in one (0.7%). Presumed alveolar haemorrhage was recorded in 19 cases (14.1%) and haemoptysis occurred in seven (5.2%). There were no significant differences between group A and group B, except for alveolar haemorrhage (P < 0.001). CONCLUSION: The accuracy and complication rate of percutaneous CT-guided biopsy of nodules smaller than 20 mm, performed using an automated 20-gauge coaxial biopsy device, are comparable to those for larger lesions. (C) 2000 The Royal College of Radiologists.
引用
收藏
页码:281 / 287
页数:7
相关论文
共 26 条
[1]   CT-guided transthoracic needle biopsy: A comparison between automated biopsy gun and fine needle aspiration [J].
Arakawa, H ;
Nakajima, Y ;
Kurihara, Y ;
Niimi, H ;
Ishikawa, T .
CLINICAL RADIOLOGY, 1996, 51 (07) :503-506
[2]  
BERQUIST TH, 1980, MAYO CLIN PROC, V55, P475
[3]  
BOCKING A, 1995, ACTA CYTOL, V39, P463
[4]   Routine addition of an automated biopsy device to fine-needle aspiration of the lung: A prospective assessment [J].
Boiselle, PM ;
Shepard, JAO ;
Mark, EJ ;
Szyfelbein, WM ;
Fan, CM ;
Slanetz, PJ ;
TrotmanDickenson, B ;
Halpern, EF ;
McLoud, TC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (03) :661-666
[5]   IMAGE-GUIDED AUTOMATED CORE BIOPSIES OF THE BREAST, CHEST, ABDOMEN, AND PELVIS [J].
BURBANK, F ;
KAYE, K ;
BELVILLE, J ;
EKUAN, J ;
BLUMENFELD, M .
RADIOLOGY, 1994, 191 (01) :165-171
[6]   Bronchoscopic diagnosis of solitary pulmonary nodules and lung masses in the absence of endobronchial abnormality [J].
Chechani, V .
CHEST, 1996, 109 (03) :620-625
[7]   SMALL BRONCHOGENIC CARCINOMAS PRESENTING AS SOLITARY PULMONARY NODULES - BIOPTIC APPROACH GUIDED BY CT-POSITIVE BRONCHUS SIGN [J].
GAETA, M ;
RUSSI, EG ;
LASPADA, F ;
BARONE, M ;
CASABLANCA, G ;
PANDOLFO, I .
CHEST, 1992, 102 (04) :1167-1170
[8]   SUPPLEMENTARY TISSUE-CORE HISTOLOGY FROM FINE-NEEDLE TRANS-THORACIC ASPIRATION BIOPSY [J].
GREENE, R ;
SZYFELBEIN, WM ;
ISLER, RJ ;
STARK, P ;
JANTSCH, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (04) :787-792
[9]   CT-GUIDED AUTOMATED NEEDLE-BIOPSY OF THE CHEST [J].
HARAMATI, LB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (01) :53-55
[10]   CT-guided biopsy of pulmonary nodules less than 3 cm: Usefulness of the spring-operated core biopsy needle and frozen-section pathologic diagnosis [J].
Hayashi, N ;
Sakai, T ;
Kitagawa, M ;
Kimoto, T ;
Inagaki, R ;
Ishii, Y ;
Noriki, S ;
Imamura, Y .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :329-331