Routine addition of an automated biopsy device to fine-needle aspiration of the lung: A prospective assessment

被引:76
作者
Boiselle, PM
Shepard, JAO
Mark, EJ
Szyfelbein, WM
Fan, CM
Slanetz, PJ
TrotmanDickenson, B
Halpern, EF
McLoud, TC
机构
[1] MASSACHUSETTS GEN HOSP,DEPT RADIOL,BOSTON,MA 02114
[2] MASSACHUSETTS GEN HOSP,DEPT PATHOL,BOSTON,MA 02114
关键词
D O I
10.2214/ajr.169.3.9275873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to prospectively assess the usefulness of the routine addition of an automated biopsy device (ABD) to fine-needle aspiration (FNA) of the lung and to examine the complication rate of this procedure. SUBJECTS AND METHODS. Fifty biopsies were performed under CT guidance using a coaxial technique with a 19-gauge introducer needle and a 22-gauge aspirating needle followed by a 20-gauge ABD. An average of 3.5 FNA specimens and 2.5 core specimens were obtained. Cytology and histology specimens were interpreted separately by two experienced pathologists who were unaware of the other's interpretation. Final diagnoses were based on surgery, microbiology, definitive biopsy diagnosis, and clinical follow-up. All complications were recorded. RESULTS, Of 34 malignant lesions, we achieved a diagnostic accuracy of 94% for FNA and 59% for core biopsy (p <.01). Combined accuracy was 94%. Of 16 benign lesions, an accurate definitive diagnosis was made in 31% of cases using FNA and in 69% of cases using core biopsy (p =.08). Combined accuracy was 69%. In the subset of benign lesions that were not acute infections (n = 8), an accurate definitive benign diagnosis was made in 12% of cases using FNA and in 75% of cases using core biopsy (p <.05). No false-positive diagnoses of malignancy occurred. Complications included pneumothorax, nine (18%) of 50 cases; chest tube, one (2%) of 50 cases; minor pulmonary hemorrhage, seven (14%) of 50 cases; and minor hemoptysis, two (4%) of 50 cases. CONCLUSION, The complication rates of FNA with the addition of an ABD are similar to those reported in the literature for FNA alone. The addition of an ABD significantly increases the diagnostic accuracy only for the subset of benign lesions that are not acute infections.
引用
收藏
页码:661 / 666
页数:6
相关论文
共 16 条
[1]   VALUE OF HAVING A CYTOPATHOLOGIST PRESENT DURING PERCUTANEOUS FINE-NEEDLE ASPIRATION BIOPSY OF LUNG - REPORT OF 55 CANCER-PATIENTS AND METAANALYSIS OF THE LITERATURE [J].
AUSTIN, JHM ;
COHEN, MB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (01) :175-177
[2]   IMAGE-GUIDED AUTOMATED CORE BIOPSIES OF THE BREAST, CHEST, ABDOMEN, AND PELVIS [J].
BURBANK, F ;
KAYE, K ;
BELVILLE, J ;
EKUAN, J ;
BLUMENFELD, M .
RADIOLOGY, 1994, 191 (01) :165-171
[3]   THORACIC NEEDLE-BIOPSY - IMPROVED RESULTS UTILIZING A TEAM-APPROACH [J].
CONCES, DJ ;
SCHWENK, GR ;
DOERING, PR ;
GLANT, MD .
CHEST, 1987, 91 (06) :813-816
[4]   THIN-NEEDLE ASPIRATION BIOPSY - METHODS OF INCREASING THE ACCURACY OF A NEGATIVE PREDICTION [J].
GOBIEN, RP ;
VALICENTI, JF ;
PARIS, BS ;
DANIELL, C .
RADIOLOGY, 1982, 145 (03) :603-605
[5]   CT-GUIDED AUTOMATED NEEDLE-BIOPSY OF THE CHEST [J].
HARAMATI, LB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (01) :53-55
[6]   TUMORS IN THE MEDIASTINUM - US-GUIDED HISTOLOGIC CORE-NEEDLE BIOPSY [J].
HEILO, A .
RADIOLOGY, 1993, 189 (01) :143-146
[7]   Sarcoidlike reaction in patients with malignancy [J].
Hunsaker, AR ;
Munden, RF ;
Pugatch, RD ;
Mentzer, SJ .
RADIOLOGY, 1996, 200 (01) :255-261
[8]   TRANS-THORACIC NEEDLE ASPIRATION BIOPSY OF BENIGN AND MALIGNANT LUNG LESIONS [J].
KHOURI, NF ;
STITIK, FP ;
EROZAN, YS ;
GUPTA, PK ;
KIM, WS ;
SCOTT, WW ;
HAMPER, UM ;
MANN, RB ;
EGGLESTON, JC ;
BAKER, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (02) :281-288
[9]   Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients [J].
Klein, JS ;
Salomon, G ;
Stewart, EA .
RADIOLOGY, 1996, 198 (03) :715-720
[10]   POSITIONAL PRECAUTIONS IN NEEDLE ASPIRATION LUNG-BIOPSY [J].
MOORE, EH ;
SHEPARD, JAO ;
MCLOUD, TC ;
TEMPLETON, PA ;
KOSIUK, JP .
RADIOLOGY, 1990, 175 (03) :733-735