Treadmill versus shuttle walk tests of walking ability in intermittent claudication

被引:39
作者
Zwierska, I
Nawaz, S
Walker, RD
Wood, RFM
Pockley, AG
Saxton, JM
机构
[1] Sheffield Hallam Univ, Ctr Sport & Exercise Sci, Sheffield S10 2BP, S Yorkshire, England
[2] Univ Sheffield, Div Clin Sci N, Sheffield, S Yorkshire, England
关键词
peripheral arterial disease; exercise testing; test-retest reliability; cardiovascular responses;
D O I
10.1249/01.MSS.0000145471.73711.66
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: To compare treadmill and shuttle walk tests for assessing functional capacity in patients with intermittent claudication, with respect to test-retest reliability, cardiovascular responses, and patient preferences. Methods: Patients with stable intermittent claudication (N = 55, ages 52-85 yr, median age 68 yr) were recruited from the Sheffield Vascular Institute at the Northern General Hospital, Sheffield, UK. Each patient performed an incremental shuttle walk test, a constant-pace shuttle walk test, and a standardized treadmill test (3.2 km(.)h(-1), 12% gradient), each on three occasions. The incremental shuttle walk began at 3 km(.)h(-1) and increased by 0.5 km(.)h(-1) every minute, whereas the constant-pace shuttle walk was performed at the fixed pace of 4 km(.)h(-1). Claudication distance (CD), maximum walking distance (MWD), heart rate (HR), and blood pressure were assessed in each testing session. The patients also completed a test preference questionnaire. Results: CD and MWD for both shuttle walks were greater than the corresponding walking distances achieved in the treadmill test (P < 0.001). Average coefficients of variation for repeated incremental shuttle walk, constant-pace shuttle walk, and treadmill tests were 15.9%, 21.1%, and 18.7%, respectively, for MWD, corresponding to average intraclass correlation coefficients of 0.87, 0.82, and 0.87. Treadmill walking evoked greater increases in HR and blood pressure (P < 0.001), and fewer patients expressed a preference for it (24 vs 43% for shuttle walking). Conclusion: These findings indicated that shuttle walk testing exhibits similar test-retest reliability as treadmill testing, but that it evoked a lower level of cardiovascular stress and is preferred to treadmill testing by a large proportion of patients.
引用
收藏
页码:1835 / 1840
页数:6
相关论文
共 26 条
[11]   Quality of life assessment in peripheral arterial disease [J].
Hiatt, WR .
ATHEROSCLEROSIS, 1997, 131 :S35-S36
[12]   CLINICAL-TRIALS FOR CLAUDICATION - ASSESSMENT OF EXERCISE PERFORMANCE, FUNCTIONAL STATUS, AND CLINICAL END-POINTS [J].
HIATT, WR ;
HIRSCH, AT ;
REGENSTEINER, JG ;
BRASS, EP .
CIRCULATION, 1995, 92 (03) :614-621
[13]  
Hiatt WR, 1988, J Cardiopulm Rehabil Prev, V12, P525, DOI DOI 10.1097/00008483-198812200-00005
[14]   HEMODYNAMIC CORRELATES OF MYOCARDIAL OXYGEN-CONSUMPTION DURING UPRIGHT EXERCISE [J].
KITAMURA, K ;
TAYLOR, HL ;
WANG, Y ;
JORGENSEN, CR ;
GOBEL, FL .
JOURNAL OF APPLIED PHYSIOLOGY, 1972, 32 (04) :516-+
[15]  
Labs KH, 1999, CIRCULATION, V100, pE75
[16]   Reliability of treadmill testing in peripheral arterial disease: a comparison of a constant load with a graded load treadmill protocol [J].
Labs, KH ;
Nehler, MR ;
Roessner, M ;
Jaeger, KA ;
Hiatt, WR .
VASCULAR MEDICINE, 1999, 4 (04) :239-246
[17]  
Labs KH, 1998, J VASC INVESTIG, V4, P55
[18]   The ankle brachial index independently predicts walking velocity and walking endurance in peripheral arterial disease [J].
McDermott, MM ;
Liu, K ;
Guralnik, JM ;
Mehta, S ;
Criqui, MH ;
Martin, GJ ;
Greenland, P .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1998, 46 (11) :1355-1362
[19]   The clinical utility of a six-minute walk test in peripheral arterial occlusive disease patients [J].
Montgomery, PS ;
Gardner, AW .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1998, 46 (06) :706-711
[20]   HEMODYNAMIC PREDICTORS OF MYOCARDIAL OXYGEN-CONSUMPTION DURING STATIC AND DYNAMIC EXERCISE [J].
NELSON, RR ;
GOBEL, FL ;
JORGENSEN, CR ;
WANG, K ;
WANG, Y ;
TAYLOR, HL .
CIRCULATION, 1974, 50 (06) :1179-1189