Targeted reinnervation for enhanced prosthetic arm function in a woman with a proximal amputation: a case study

被引:367
作者
Kuiken, Todd A. [1 ]
Miller, Laura A.
Lipschutz, Robert D.
Lock, Blair A.
Stubblefield, Kathy
Marasco, Paul D.
Zhou, Ping
Dumanian, Gregory A.
机构
[1] Rehabil Inst Chicago, Neural Engn Ctr Artificial Limbs, Chicago, IL 60611 USA
[2] Northwestern Univ, Feinberg Sch Med, Dept Phys Med & Rehabil, Chicago, IL 60611 USA
[3] Northwestern Univ, Feinberg Sch Med, Dept Surg, Div Plast Surg, Chicago, IL 60611 USA
[4] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
关键词
D O I
10.1016/S0140-6736(07)60193-7
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background The function of current artificial arms is limited by inadequate control methods. We developed a technique that used nerve transfers to muscle to develop new electromyogram control signals and nerve transfers to skin, to provide a pathway for cutaneous sensory feedback to the missing hand. Methods We did targeted reinnervation surgery on a woman with a left arm amputation at the humeral neck. The ulnar, median, musculocutaneous, and distal. radial nerves were transferred to separate segments of her pectoral and serratus muscles. Two sensory nerves were cut and the distal ends were anastomosed to the ulnar and median nerves. After full recovery the patient was fit with a new prosthesis using the additional targeted muscle reinnervation sites. Functional testing was done and sensation in the reinnervated skin was quantified. Findings The patient described the control as intuitive; she thought about using her hand or elbow and the prosthesis responded appropriately. Functional testing showed substantial improvement: mean scores in the blocks and box test increased from 4.0 (SD 1.0) with the conventional prosthesis to 15.6 (1.5) with the new prosthesis. Assessment of Motor and Process Skills test scores increased from 0.30 to 1.98 for motor skills and from 0.90 to 1.98 for process skills. The denervated anterior chest skin was reinnervated by both the ulnar and median nerves; the patient felt that her hand was being touched when this chest skin was touched, with near-normal thresholds in all sensory modalities. Interpretation Targeted reinnervation improved prosthetic function and ease of use in this patient. Targeted sensory reinnervation provides a potential pathway for meaningful sensory feedback.
引用
收藏
页码:371 / 380
页数:10
相关论文
共 30 条
[1]
Using EMG to anticipate head motion for virtual-environment applications [J].
Barniv, Y ;
Aguilar, M ;
Hasanbelliu, E .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (06) :1078-1093
[2]
BELL JA, 1995, SENSIBILITY TESTING
[3]
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve [J].
Branner, A ;
Stein, RB ;
Fernandez, E ;
Aoyagi, Y ;
Normann, RA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (01) :146-157
[4]
Using multi-neuron population recordings for neural prosthetics [J].
Chapin, JK .
NATURE NEUROSCIENCE, 2004, 7 (05) :452-455
[5]
A real-time EMG pattern recognition system based on linear-nonlinear feature projection for a multifunction myoelectric hand [J].
Chu, Jun-Uk ;
Moon, Inhyuk ;
Mun, Mu-Seong .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (11) :2232-2239
[6]
Crampon MA, 2002, BIO-MED MATER ENG, V12, P397
[7]
Classification of the intention to generate a shoulder versus elbow torque by means of a time-frequency synthesized spatial patterns BCI algorithm [J].
Deng, Jie ;
Yao, Jun ;
Dewald, Julius P. A. .
JOURNAL OF NEURAL ENGINEERING, 2005, 2 (04) :131-138
[8]
Direct neural sensory feedback and control of a prosthetic arm [J].
Dhillon, GS ;
Horch, KW .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (04) :468-472
[9]
Connecting cortex to machines: recent advances in brain interfaces [J].
Donoghue, JP .
NATURE NEUROSCIENCE, 2002, 5 (Suppl 11) :1085-1088
[10]
DYCK PJ, 2005, QUANTITATIVE SENSATI