Multivariate prediction of eight kerosene properties employing vapour-phase mid-infrared spectrometry

被引:22
作者
Gómez-Carracedo, MP [1 ]
Andrade, JM [1 ]
Calviño, M [1 ]
Fernández, E [1 ]
Prada, D [1 ]
Muniategui, S [1 ]
机构
[1] Univ A Coruna, Dept Analyt Chem, E-15071 La Coruna, Spain
关键词
vapour-phase; kerosene; infrared spectroscopy; partial least squares regression; quality control;
D O I
10.1016/S0016-2361(02)00381-2
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Eight physico-chemical properties of kerosene (aviation jet fuel) are predicted employing vapour-phase generation, Fourier transform mid-infrared (FT-MIR) spectra and partial least squares regression (PLS). Two devices were implemented and studied in order to generate the kerosene vapour from 100 liquid samples from a Spanish refinery. One of them is very simple whilst the other one requires thermostatic and gas flow controls. The FT-MIR spectra are recorded and used to deploy PLS models for each property (distillation curve, flash point, freezing point, percentage of aromatics and viscosity) and each device. In general, the simplest device yields the more satisfactory models. Several criteria are used to evaluate their performance: the average prediction error (corrected to take into account the error in the reference values), the F-test to assess the absence of bias in the predictions, repeatability and reproducibility. In general, all the models provide unbiased predictions, with low average errors and good precision. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1211 / 1218
页数:8
相关论文
共 30 条
[1]   A review of the main factors influencing the FT-IR-PLS abilities exemplified with petrochemical qualimetric applications [J].
Andrade, JM ;
Garcia, MV ;
LopezMahia, P ;
Prada, D .
TALANTA, 1997, 44 (12) :2167-2184
[2]   Applicability of high-absorbance MIR spectroscopy in industrial quality control of reformed gasolines [J].
Andrade, JM ;
Sánchez, MS ;
Sarabia, LA .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (01) :41-55
[3]   Use of multivariate techniques in quality control of kerosene production [J].
Andrade, JM ;
Muniategui, S ;
LopezMahia, P ;
Prada, D .
FUEL, 1997, 76 (01) :51-59
[4]   Comparison of near-infrared and mid-infrared spectroscopy for the determination of distillation property of kerosene [J].
Chung, H ;
Ku, MS ;
Lee, JS .
VIBRATIONAL SPECTROSCOPY, 1999, 20 (02) :155-163
[5]  
Deane J.M., 1989, J CHEMOMETR, V3, P477
[6]   EXAMINATION OF SOME MISCONCEPTIONS ABOUT NEAR-INFRARED ANALYSIS [J].
DIFOGGIO, R .
APPLIED SPECTROSCOPY, 1995, 49 (01) :67-75
[7]  
DYROFF GV, 1998, ASTM MANUAL SERIES
[8]   Improved prediction error estimates for multivariate calibration by correcting for the measurement error in the reference values [J].
Faber, K ;
Kowalski, BR .
APPLIED SPECTROSCOPY, 1997, 51 (05) :660-665
[9]   Analysis of gasolines by FT-IR spectroscopy [J].
Fodor, GE ;
Kohl, KB ;
Mason, RL .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :23-30
[10]   ANALYSIS OF MIDDLE DISTILLATE FUELS BY MIDBAND INFRARED-SPECTROSCOPY [J].
FODOR, GE ;
KOHL, KB .
ENERGY & FUELS, 1993, 7 (05) :598-601