Assessment of visual function after corneal transplantation: The quality of life and psychometric assessment after corneal transplantation (Q-PACT) study

被引:48
作者
Mendes, F
Schaumberg, DA
Navon, S
Steinert, R
Sugar, J
Holland, EJ
Dana, MR
机构
[1] Harvard Univ, Sch Med, Schepens Eye Res Inst, Dept Ophthalmol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Massachusetts Eye & Ear Infirm, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Brigham & Womens Hosp, Div Prevent Med,Dept Med, Boston, MA 02114 USA
[4] Carolina Eye Associates, Charlotte, NC USA
[5] Harvard Univ, Sch Med, Dept Ophthalmol, Boston, MA USA
[6] Ophthalmol Consultants Boston, Boston, MA USA
[7] Univ Illinois, Eye & Ear Infirm, Chicago, IL 60612 USA
[8] Univ Minnesota, Minneapolis, MN 55455 USA
[9] Univ Cincinnati, Cincinnati, OH 45221 USA
关键词
D O I
10.1016/S0002-9394(02)02278-X
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: Many patients with successful corneal grafts have poor vision postoperatively. This study evaluates changes in vision,related quality of life after penetrating keratoplasty (PK). DESIGN: Multicenter prospective cohort study. METHODS: Penetrating keratoplasty candidates from the university-affiliated ophthalmology clinics of four participating centers were enrolled and followed up prospectively. We used the PK-VFQ, a modified version of the Visual Function Index-14, combined with clinical examinations before and at 6 and 12 months after PK. We used multivariate linear regression models to examine predictors of change in PK-VFQ scores. RESULTS: We studied 74 grafts in 71 eyes of 67 patients aged 23 to 91 (mean, 61) years who were followed up for at least 6 months. Indications for surgery included bullous keratopathy (27%), scarring (16%), keratoconus (16%), dystrophies (16%), and regrafts (15%). Median preoperative visual acuity was 20/200 in the graft candidate and 20/30 in the best eye. Median best-corrected postoperative visual acuity in the operated eyes was 20/60 at 6 months. PK-VFQ scores improved at 6 months in 79% by an average of 13.0 points (range, - 16.7 to 67.5). Improvement in PK-VFQ scores was associated with younger age (P =.04), poorer preoperative visual acuity in the best eye (P =.001), and postoperative contact lens use (P =.04) but not with postoperative acuity in the grafted eye (P =.49). Postoperatively, 80% of patients were moderately to very satisfied with their vision, and 97% of patients stated they would have the surgery again. CONCLUSIONS: Improvement in visual function is inversely associated with visual acuity in the better-seeing eye but does not correlate with the postoperative acuity in the grafted eye. Although most keratoplasties are done unilaterally in the setting of good visual acuity in the contralateral eye, for the majority of patients visual function improves after PK. (C) 2003 by Elsevier Inc. All rights reserved.
引用
收藏
页码:785 / 793
页数:9
相关论文
共 24 条
[1]   International applicability of the VF-14 - An index of visual function in patients with cataracts [J].
Alonso, J ;
Espallargues, M ;
Anderson, TF ;
Cassard, SD ;
Dunn, E ;
BernthPetersen, P ;
Norregaard, JC ;
Black, C ;
Steinberg, EP ;
Anderson, GF .
OPHTHALMOLOGY, 1997, 104 (05) :799-807
[2]  
[Anonymous], 1993, MANUAL INTERPRETATIO
[3]   The VF-14 index of functional visual impairment in candidates for a corneal graft [J].
Boisjoly, H ;
Gresset, J ;
Fontaine, N ;
Charest, M ;
Brunette, I ;
LeFrançois, M ;
Deschênes, J ;
Bazin, R ;
Laughrea, PA ;
Dubé, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (01) :38-44
[4]   The VF-14 index of visual function in recipients of a corneal graft:: A 2-year follow-up study [J].
Boisjoly, H ;
Gresset, J ;
Charest, M ;
Fontaine, N ;
Brunette, I ;
Lefrançois, M ;
Laughrea, PA ;
Bazin, R ;
Dubé, I ;
Deschênes, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (02) :166-171
[5]  
Brown G C, 1999, Trans Am Ophthalmol Soc, V97, P473
[6]  
CHERRY PMH, 1979, ANN OPHTHALMOL, V11, P669
[7]  
Jensen A D, 1974, Trans Am Ophthalmol Soc, V72, P123
[8]  
KRACHNER J, 1998, CORNEA TEXT COLOR 8
[9]  
Musch DC, 1997, AM J OPHTHALMOL, V124, P1
[10]  
Navon SE, 1996, P AM AC CENT C CHIC, P133