Ambient imaging mass spectrometry by electrospray ionization using solid needle as sampling probe

被引:84
作者
Chen, Lee Chuin [1 ]
Yoshimura, Kentaro [2 ]
Yu, Zhan [1 ,3 ]
Iwata, Rikiya [1 ]
Ito, Hajime [1 ]
Suzuki, Hiroaki [4 ]
Mori, Kunihiko [4 ]
Ariyada, Osamu [4 ]
Takeda, Sen [2 ]
Kubota, Takeo [5 ]
Hiraoka, Kenzo [1 ]
机构
[1] Yamanashi Univ, Clean Energy Res Ctr, Kofu, Yamanashi 4008511, Japan
[2] Univ Yamanashi, Fac Med, Dept Anat & Cell Biol, Chuo 4093898, Japan
[3] Shenyang Normal Univ, Coll Chem & Biol, Shenyang 110034, Peoples R China
[4] Arios Inc, Tokyo 1960021, Japan
[5] Univ Yamanashi, Fac Med, Dept Epigenet Med, Chuo 4093898, Japan
来源
JOURNAL OF MASS SPECTROMETRY | 2009年 / 44卷 / 10期
关键词
imaging mass spectrometry; electrospray ionization; ambient sampling probe; solid needle; mouse brain section; BIOLOGICAL SAMPLES; ATMOSPHERIC-PRESSURE; SURFACE; PROTEINS; PEPTIDES; TISSUE; GENERATION; SYSTEM; BRAIN; WIRE;
D O I
10.1002/jms.1632
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although being an atmospheric pressure ion source, electrospray ionization (ESI) has rarely been used directly for ambient imaging mass spectrometry because the sample has to be introduced as liquid solution through the capillary. Instead of capillary, probe electrospray ionization (PESI), which has been developed recently, uses a solid needle as the sampling probe, as well as the electrospray emitter, and has been applied not only for liquid solutions but also for the direct sampling on wet samples. Biological tissues are composed of cells that contain 70-90% water, and when the surface is probed by the needle tip, the biological fluid adhering to the needle can be electrosprayed directly or assisted by additional solvent added onto the needle surface. Here, we demonstrate ambient imaging mass spectrometry of mouse brain section using PESI, incorporated with an auxiliary heated capillary sprayer. The solvent vapor generated from the sprayer condensed on the needle tip, re-dissolving the adhered sample, and at the same time, providing an indirect means for needle cleaning. The histological sections were prepared by fixation using paraformaldehyde, and the spatial analysis was automated by maintaining an equal sampling depth into the sample in addition to raster scan. Phospholipids and galactosylceramides were readily detected from the mouse brain section in the positive ion mode, and were mapped with 60 gm lateral resolution to form mass spectrometric images. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:1469 / 1477
页数:9
相关论文
共 35 条
[1]   Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS [J].
Caprioli, RM ;
Farmer, TB ;
Gile, J .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4751-4760
[2]   Characteristics of probe electrospray generated from a solid needle [J].
Chen, Lee Chuin ;
Nishidate, Kentaro ;
Saito, Yuta ;
Mori, Kunihiko ;
Asakawa, Daiki ;
Takeda, Sen ;
Kubota, Takeo ;
Hori, Hirokazu ;
Hiraoka, Kenzo .
JOURNAL OF PHYSICAL CHEMISTRY B, 2008, 112 (35) :11164-11170
[3]   Application of probe electrospray to direct ambient analysis of biological samples [J].
Chen, Lee Chuin ;
Nishidate, Kentaro ;
Saito, Yuta ;
Mori, Kunihiko ;
Asakawa, Daiki ;
Takeda, Sen ;
Kubota, Takeo ;
Terada, Nobuo ;
Hashimoto, Yutaka ;
Hori, Hirokazu ;
Hiraoka, Kenzo .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (15) :2366-2374
[4]   Atomic and molecular imaging at the single-cell level with TOF-SIMS [J].
Colliver, TL ;
Brummel, CL ;
Pacholski, ML ;
Swanek, FD ;
Ewing, AG ;
Winograd, N .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2225-2231
[5]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[6]  
Ford MJ, 2004, RAPID COMMUN MASS SP, V18, P1303, DOI 10.1002/rcm.1486
[7]   LASER MICROPROBE MASS ANALYSIS OF ORGANIC MATERIALS [J].
HILLENKAMP, F ;
UNSOLD, E ;
KAUFMANN, R ;
NITSCHE, R .
NATURE, 1975, 256 (5513) :119-120
[8]   Development of probe electrospray using a solid needle [J].
Hiraoka, Kenzo ;
Nishidate, Kentaro ;
Mori, Kunihiko ;
Asakawa, Daiki ;
Suzuki, Shigeo .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (18) :3139-3144
[9]  
Hong CM, 1999, RAPID COMMUN MASS SP, V13, P21, DOI 10.1002/(SICI)1097-0231(19990115)13:1<21::AID-RCM441>3.0.CO
[10]  
2-7