Slurry sampling electrothermal atomic absorption spectrometry for trace element analysis of high-purity tungsten trioxide

被引:21
作者
Krivan, V [1 ]
Heger, A [1 ]
Hauptkorn, S [1 ]
机构
[1] Univ Ulm, Sekt Analyt & Hochstreinigung, D-89069 Ulm, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1998年 / 360卷 / 02期
关键词
D O I
10.1007/s002160050669
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A slurry sampling ETAAS method for the determination of trace concentrations of Ca, Co, Cr, Cu, Fe, K, Mg, Na and Ni in tungsten trioxide is presented. A high background absorption appearing with large sample amounts during atomization at high temperatures was the only matrix interference observed. It could be significantly reduced by volatilization of the matrix in the pyrolysis step. Calibration curves recorded with aqueous standards could be used for calibration in all cases excluding the de termination of very low analyte concentrations of Co and Fe which required the use of the standard additions method. The results obtained by this method showed an excellent agreement with those determined in digests by ETAAS. The detection limits achievable by the slurry technique were between 1 (Ca, K, ME, Na) and 210 (Cu) ng/g. They were mostly by more than one order of magnitude better than those of the solution techniques.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 33 条
[1]  
AVRAMENKO LI, 1992, ZH ANAL KHIM, V47, P737
[2]  
BLODORN W, 1989, MIKROCHIM ACTA, P423
[3]   LINE SELECTION AND DETERMINATION OF TRACE AMOUNTS OF ELEMENTS IN TUNGSTEN BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CARRE, M ;
DERODRIGUEZ, OD ;
MERMET, JM ;
BRIDENNE, M ;
MAROT, Y .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (01) :49-55
[4]  
DIESBURG DE, 1989, P 12 PLANS SEM, V3, P371
[5]   DETERMINATION OF TRACE-ELEMENTS IN HIGH-PURITY MOLYBDENUM TRIOXIDE BY SLURRY SAMPLING ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
DOCEKAL, B ;
KRIVAN, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (04) :637-641
[6]   ANALYSIS OF SILICON-NITRIDE POWDERS FOR AL, CR, CU, PA, K, MG, MN, NA, AND ZN BY SLURRY-SAMPLING ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
FRIESE, KC ;
KRIVAN, V .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :354-359
[7]   DETERMINATION OF SILICON IN TITANIUM-DIOXIDE AND ZIRCONIUM DIOXIDE BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING THE SLURRY SAMPLING TECHNIQUE [J].
HAUPTKORN, S ;
SCHNEIDER, G ;
KRIVAN, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :463-468
[8]   Solution and slurry sampling electrothermal atomic absorption spectrometry for the analysis of high purity quartz [J].
Hauptkorn, S ;
Krivan, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (9-10) :1197-1210
[9]   ELECTROTHERMAL AAS DETERMINATION OF BISMUTH, ANTIMONY AND TIN IN HIGH-PURITY WO3 [J].
HAVEZOV, I ;
JORDANOV, N ;
ORTNER, HM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (12) :871-873
[10]   ULTRA-TRACE ANALYSIS OF U, TH, CA AND SELECTED HEAVY-METALS IN HIGH-PURITY REFRACTORY-METALS WITH ISOTOPE-DILUTION MASS-SPECTROMETRY [J].
HERZNER, P ;
HEUMANN, KG .
MIKROCHIMICA ACTA, 1992, 106 (3-6) :127-135