Use of pulsed field gel electrophoresis to determine the source of microbial contamination of central venous catheters

被引:17
作者
Livesley M.A. [1 ]
Tebbs S.E. [2 ]
Moss H.A. [2 ]
Faroqui M.H. [3 ]
Lambert P.A. [1 ]
Elliott T.S.J. [2 ]
机构
[1] Dept. Pharmaceutical and Biol. Sci., Aston University, Birmingham, B4 7ET, Aston Triangle
[2] Department of Clinical Microbiology, Queen Elizabeth Hospital, Edgbaston, Birmingham
[3] Dept. of Anaesth. and Intensive Care, Queen Elizabeth Hospital, Edgbaston, Birmingham
关键词
Central venous catheter; Pulsed-field gel electrophoresis;
D O I
10.1007/BF01682166
中图分类号
学科分类号
摘要
Microorganisms detected in situ on the distal tip of central venous catheters (CVC) within 90 min of insertion were investigated using pulsed-field gel electrophoresis to analyse genomic fragments obtained with the SmaI restriction enzyme. Thirty patients received a triple lumen CVC, which was inserted directly through the skin using the Seldinger technique. In a further 30 patients a triple lumen CVC was inserted through a Swan sheath, thereby avoiding direct contact of the CVC with the skin. Staphylococci were isolated from the distal tips of the catheters in 6 patients (5 who had the CVC inserted directly through the skin and 1 who had the CVC inserted via a Swan sheath.) Twenty-three staphylococcal isolates were also isolated from the insertion equipment and the skin swabs surrounding the insertion site of these six patients. All the isolates were genotyped. In one of the patients the organisms isolated from the skin were identical to those on the CVC tip. In two further patients similar organisms were isolated from the insertion equipment and the patients' skin. These results, in addition to the reduced colonisation rates observed when catheters were introduced through a Swan sheath, support the hypothesis that microorganisms from the skin are impacted onto the CVC tip and the CVC insertion equipment at catheter insertion.
引用
收藏
页码:108 / 112
页数:4
相关论文
共 17 条
[1]  
Archer G.L., Staphylococcus epidermidis and other coagulase-negative staphylococci, Principles of Infectious Diseases, pp. 1511-1518, (1990)
[2]  
Douard M.C., Clementi E., Arlet G., Negative catheter tip cultures and diagnosis of catheter related bacteraemia, Nutrition, 10, pp. 397-404, (1994)
[3]  
Maki D.G., Stolz S.S., Wheeler S., Mermel L.A., A prospective randomised trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: Implications for catheter management, Critical Care Medicine, 22, pp. 1729-1737, (1994)
[4]  
Elliott T.S.J., Intra-vascular-device infections, Journal of Medical Microbiology, 27, pp. 161-167, (1988)
[5]  
Elliott T.S.J., Line associated bacteraemias, Communicable Diseases Report, 3, pp. 91-95, (1993)
[6]  
Moss H.A., Elliott T.S.J., The cost of infections related to central venous catheters designed for long-term use, British Journal of Medical Microbiology, 11, pp. 1-7, (1997)
[7]  
Sitges-Serra A., Puig P., Linares J., Perez J.L., Farrero N., Jaurrieta E., Garau J., Hub colonisation as the initial step in an outbreak of catheter-related sepsis due to a coagulase-negative staphylococci during parenteral nutrition, Journal of Parenteral and Enteral Nutrition, 8, pp. 668-672, (1984)
[8]  
Elliott T.S.J., Moss H.A., Tebbs S.E., Wilson I.C., Bonser R.S., Graham T.R., Burke L.P., Faroqui M.H., A novel approach to investigate the source of microbial contamination of central venous catheters, European Journal of Clinical Microbiology & Infectious Diseases, 16, pp. 210-213, (1997)
[9]  
Mermel L.A., McCormick R.D., Springman S.R., Maki D.G., The pathogenesis and epidemiology of catheter related infections with pulmonary artery Swan Ganz catheters: A prospective study utilizing molecular subtyping, American Journal of Medicine, SUPPL. 3B, (1997)
[10]  
Tan T.Q., Musser J.M., Shulman R.J., Molecular epidemiology of coagulase negative staphylococcus blood isolates from neonates with persistent bacteraemia and children with central venous catheter infections, Journal of Infectious Diseases, 169, pp. 1393-1397, (1994)