Biomaterials in urology

被引:12
作者
Darren T. Beiko
Bodo E. Knudsen
James D. Watterson
John D. Denstedt
机构
[1] Division of Urology, St. Joseph’s Health Care London, 268 Grosvenor Street, London, N6A 4V2, ON
关键词
Biocompatibility Testing; Nephrostomy Tube; Oxalobacter Formigenes; Ureteral Stents; Urethral Catheter;
D O I
10.1007/s11934-003-0057-4
中图分类号
学科分类号
摘要
Biomaterials such as urethral catheters, urethral stents, and ureteral stents are commonly used in patients with urologic disorders. There are currently many different bulk materials and coatings available for the manufacture of urinary tract biomaterials; however, the ideal material has yet to be discovered. Any potential biomaterial must undergo rigorous physical and biocompatibility testing before commercialization and use in humans. Despite significant advances in basic science research involving biocompatibility issues and biofilm formation, infection and encrustation remain associated with the use of biomaterials in the urinary tract, and therefore, limit their long-term use. This review critically evaluates the literature published over the past 12 months, providing an update on the current status of naturally derived and synthetic polymeric biomaterial use in the urinary tract. We focus on urethral catheters, urethral stents, and ureteral stents. We discuss issues of biocompatibility and new approaches to biocompatibility testing, biomaterials currently available for use, new biomaterials and coatings, and novel ureteral stent designs. Finally, we discuss the future of biomaterial use in the urinary tract. © 2003, Current Science Inc.
引用
收藏
页码:51 / 55
页数:4
相关论文
共 30 条
[11]  
Lam J.S., Volpe M.A., Kaplan S.A., Use of prostatic stents for the treatment of benign prostatic hyperplasia in high-risk patients, Curr Urol Rep, 2, pp. 277-284, (2001)
[12]  
Kulkarni R.P., Bellamy E.A., A new thermo-expandable shapememory nickel-titanium alloy stent for the management of ureteric strictures, BJU Int, 83, pp. 755-759, (1999)
[13]  
Laaksovirta S., Laurila M., Isotalo T., Et al., Rabbit muscle and urethral in situ biocompatibility properties of the selfreinforced L-lactide-glycolic acid copolymer 80:20 spiral stent, J Urol, 167, pp. 1527-1531, (2002)
[14]  
Laaksovirta S., Isotalo T., Talja M., Et al., Interstitial laser coagulation and biodegradable self-expandable, self-reinforced poly-L-lactic and poly-L-glycolic copolymer spiral stent in the treatment of benign prostatic enlargement, J Endourol, 16, pp. 311-315, (2002)
[15]  
Ko G.Y., Kim G.C., Seo T.S., Et al., Covered, retrievable, expandable urethral nitinol stent: feasibility study in dogs, Radiology, 223, pp. 83-90, (2002)
[16]  
Tunney M.M., Gorman S.P., Evaluation of a poly(vinyl pyrollidone)-coated biomaterial for urological use, Biomaterials, 23, pp. 4601-4608, (2002)
[17]  
Stickler D.J., Evans A., Morris N., Hughes G., Strategies for the control of catheter encrustation, Int J Antimicrob Agents, 19, pp. 499-506, (2002)
[18]  
Riedl C.R., Witkowski M., Plas E., Pflueger H., Heparin coating reduces encrustation of ureteral stents: a preliminary report, Int J Antimicrob Agents, 19, pp. 507-510, (2002)
[19]  
Zupkas P., Parsons C.L., Percival C., Monga M., Pentosanpolysulfate coating of silicone reduces encrustation, J Endourol, 14, pp. 483-488, (2000)
[20]  
Sidhu H., Ogden S.D., Lung H.Y., Et al., DNA sequencing and expression of the formyl coenzyme A transferase gene, frc, from Oxalobacter formigenes, J Bacteriol, 179, pp. 3378-3381, (1997)