Using EEG to monitor anesthesia drug effects during surgery

被引:86
作者
Jameson L.C. [1 ]
Sloan T.B. [1 ]
机构
[1] Department of Anesthesiology, University of Colorado at Denver, Health Sciences Center, Denver, CO 80262
关键词
Anesthesia; Electroencephalography; Monitoring;
D O I
10.1007/s10877-006-9044-x
中图分类号
学科分类号
摘要
The use of processed electroencephalography (EEG) using a simple frontal lead system has been made available for assessing the impact of anesthetic medications during surgery. This review discusses the basic principles behind these devices. The foundations of anesthesia monitoring rest on the observations of Guedel with ether that the depth of anesthesia relates to the cortical, brainstem and spinal effects of the anesthetic agents. Anesthesiologists strive to have a patient who is immobile, is unconscious, is hemodynamically stable and who has no intraoperative awareness or recall. These anesthetic management principles apply today, despite the absence of ether from the available anesthetic medications. The use of the EEG as a supplement to the usual monitoring techniques rests on the observation that anesthetic medications all alter the synaptic function which produces the EEG. Frontal EEG can be viewed as a surrogate for the drug effects on the entire central nervous system (CNS). Using mathematical processing techniques, commercial EEG devices create an index usually between 0 and 100 to characterize this drug effect. Critical aspects of memory formation occur in the frontal lobes making EEG monitoring in this area a possible method to assess risk of recall. Integration of processed EEG monitoring into anesthetic management is evolving and its ability to characterize all of the anesthetic effects on the CNS (in particular awareness and recall) and improve decision making is under study. © Springer 2006.
引用
收藏
页码:445 / 472
页数:27
相关论文
共 171 条
[71]  
March P.A., Muir W.W., Bispectral analysis of the electroencephalogram: A review of its development and use in anesthesia, Vet Anaesth Analg, 32, pp. 241-255, (2005)
[72]  
John E.R., Prichep L.S., Kox W., Valdes-Sosa P., Bosch-Bayard J., Aubert E., Tom M., di Michele F., Gugino L.D., Invariant reversible QEEG effects of anesthetics, Conscious Cogn, 10, pp. 165-183, (2001)
[73]  
Baars J.H., Tas S., Herold K.F., Hadzidiakos D.A., Rehberg B., The suppression of spinal F-waves by propofol does not predict immobility to painful stimuli in humans{dagger}, Br J Anaesth, 96, pp. 118-126, (2006)
[74]  
Baars B.J., The brain basis of a "consciousness monitor": Scientific and medical significance, Conscious Cogn, 10, pp. 159-164, (2001)
[75]  
Bickford R., Automatic electroencephalographic control of general anesthesia, Electroencephalogr Clin Neurophysiol, 2, pp. 93-96, (1950)
[76]  
Traast H.S., Kalkman C.J., Electroencephalographic characteristics of emergence from propofol/ sufentanil total intravenous anesthesia, Anesth Analg, 81, pp. 366-371, (1995)
[77]  
Casati A., Fanelli G., Casaletti E., Colnaghi E., Cedrati V., Torri G., Clinical assessment of target-controlled infusion of propofol during monitored anesthesia care, Can J Anaesth, 46, pp. 235-239, (1999)
[78]  
Bauerle K., Greim C.A., Schroth M., Geisselbrecht M., Kobler A., Roewer N., Prediction of depth of sedation and anaesthesia by the Narcotrend EEG monitor, Br J Anaesth, 92, pp. 841-845, (2004)
[79]  
Berkenbosch J.W., Fichter C.R., Tobias J.D., The correlation of the bispectral index monitor with clinical sedation scores during mechanical ventilation in the pediatric intensive care unit, Anesth Analg, 94, pp. 506-511, (2002)
[80]  
Ibrahim A.E., Taraday J.K., Kharasch E.D., Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol, Anesthesiology, 95, pp. 1151-1159, (2001)