Preoperative coronary risk assessment with dual-source CT in patients undergoing noncoronary cardiac surgery

被引:11
作者
Buffa, V. [1 ]
De Cecco, C. N. [1 ,3 ]
Cossu, L. [2 ,4 ]
Fedeli, S. [1 ]
Vallone, A. [1 ]
Ruopoli, R. [1 ]
Luzietti, M. [1 ]
Angelica, G. [2 ]
David, V. [3 ]
Musumeci, F. [2 ]
机构
[1] Osped San Camillo Forlanini, Dipartimento Radiol Cardiovasc, Rome, Italy
[2] Osped San Camillo Forlanini, Dipartimento Cardiochirurg, Rome, Italy
[3] Univ Roma Sapienza, Dipartimento Sci Radiol, Osped St Andrea, I-00189 Rome, Italy
[4] Univ Roma Sapienza, Dipartimento Med Sperimentale, I-00189 Rome, Italy
来源
RADIOLOGIA MEDICA | 2010年 / 115卷 / 07期
关键词
Dual-source computed tomography; Coronary disease; Cardiac surgery; Major adverse cardiac events; Coronary angiography; SPIRAL COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; ARTERY-DISEASE; IMAGE QUALITY; INITIAL-EXPERIENCE; 1ST EXPERIENCE; VALVE SURGERY; TASK-FORCE; HEART-RATE; ANGIOGRAPHY;
D O I
10.1007/s11547-010-0543-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. The aim of our work was to assess the role of dual-source computed tomography (DSCT) in the preoperative evaluation of coronary artery disease in patients scheduled for noncoronary cardiac surgery. Materials and methods. One hundred patients were prospectively evaluated. Patients negative for coronary disease at DSCT (n=81) underwent surgery without coronary angiography. Patients positive for significant lesions or with nondiagnostic image quality due to artefacts or severe calcifications underwent coronary angiography (n=19) and were excluded from the study. patients who underwent surgery with only a DSCT diagnosis, we evaluated the frequency of major adverse cardiac events (MACEs) during the perioperative period and at 3 months follow-up. Results. No MACEs were recorded during the perioperative period; three noncardiac complications surgical revision for bleeding, one cardiac tamponade one respiratory insufficiency) and one death related to severe respiratory insufficiency were observed. None of the 80 patients had MACEs during the 3-month follow-up period. Conclusions. Coronary evaluation with DSCT is able to rule out the presence of coronary disease in patients scheduled for cardiac surgery, without the need for coronary angiography confirmation. Patients with significant stenosis or nondiagnostic image quality should be referred for coronary angiography.
引用
收藏
页码:1028 / 1037
页数:10
相关论文
共 28 条
  • [1] Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience
    Achenbach, S
    Ropers, D
    Kuettner, A
    Flohr, T
    Ohnesorge, B
    Bruder, H
    Theessen, H
    Karakaya, M
    Daniel, WG
    Bautz, W
    Kalender, WA
    Anders, K
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) : 331 - 335
  • [2] Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound
    Achenbach, S
    Moselewski, F
    Ropers, D
    Ferencik, M
    Hoffmann, U
    MacNeill, B
    Pohle, K
    Baum, U
    Anders, K
    Jang, I
    Daniel, WG
    Brady, TJ
    [J]. CIRCULATION, 2004, 109 (01) : 14 - 17
  • [3] Austen W G, 1975, Circulation, V51, P5
  • [4] American College of Cardiology/Society for Cardiac Angiography and Interventions clinical expert consensus document on Cardiac Catheterization Laboratory standards - A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    Bashore, TM
    Bates, ER
    Berger, PB
    Clark, DA
    Cusma, JT
    Dehmer, GJ
    Kern, MJ
    Laskey, WK
    O'Laughlin, MP
    Oesterle, S
    Popma, JJ
    O'Rourke, RA
    Abrams, J
    Bates, ER
    Brodie, BR
    Douglas, PS
    Gregoratos, G
    Hlatky, MA
    Hochman, JS
    Kaul, S
    Tracy, CM
    Waters, DD
    Winters, WL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (08) : 2170 - 2214
  • [5] Dual-source CT for visualization of the coronary arteries in heart transplant patients with high heart rates
    Bastarrika, Gorka
    Nicola De Cecco, Carlo
    Arraiza, Maria
    Mastrobuoni, Stefano
    Pueyo, Jesus C.
    Ubilla, Matias
    Rabago, Gregorio
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) : 448 - 454
  • [6] 64-slice computed tomography coronary angiography: Diagnostic accuracy in the real world
    Cademartiri F.
    Maffei E.
    Notarangelo F.
    Ugo F.
    Palumbo A.
    Lina D.
    Aldrovandi A.
    Solinas E.
    Reverberi C.
    Menozzi A.
    Vignali L.
    Malagò R.
    Midiri M.
    Mollet N.R.
    Cervellin G.
    Ardissino D.
    [J]. La radiologia medica, 2008, 113 (2) : 163 - 180
  • [7] De Cecco C N, 2008, Minerva Cardioangiol, V56, P587
  • [8] Radiation risk from coronary artery disease imaging: how do different diagnostic tests compare?
    Einstein, Andrew J.
    [J]. HEART, 2008, 94 (12) : 1519 - 1521
  • [9] Radiation dose to patients from cardiac diagnostic imaging
    Einstein, Andrew J.
    Moser, Kevin W.
    Thompson, Randall C.
    Cerqueira, Manuel D.
    Henzlova, Milena J.
    [J]. CIRCULATION, 2007, 116 (11) : 1290 - 1305
  • [10] Noninvasive imaging of the coronary arteries using a 64-row multidetector CT scanner: initial clinical experience and radiation dose concerns
    Francone, M.
    Napoli, A.
    Carbone, I.
    Cavacece, M.
    Nardis, P. G.
    Lanciotti, K.
    Visconti, S.
    Bertoletti, L.
    Di Castro, E.
    Catalano, C.
    Passariello, R.
    [J]. RADIOLOGIA MEDICA, 2007, 112 (01): : 31 - 46