Patient Self-Management of Oral Anticoagulant Therapy: An International Update

被引:5
作者
Alan K. Jacobson
机构
[1] Loma Linda VA Medical Center,Cardiology Section (111C)
关键词
anticoagulants; point-of-care systems; prothrombin time; warfarin;
D O I
10.1023/A:1013280702839
中图分类号
学科分类号
摘要
The clinical use of oral anticoagulant therapy has been complicated by the necessity for frequent determinations of the prothrombin time (PT) to ensure safety and therapeutic efficacy. This requirement has often imposed a significant burden on both providers and patients. In 1985 a German patient, Heike Möller-Jung, initiated her own patient self-testing (PST) and patient self-management (PSM). Today there are over 15,000 patients in Germany managing their oral anticoagulant therapy with PSM options. Pilot PST and PSM programs are in place in many other countries. In the United States, two devices have recently been approved for PST. This method of monitoring has been shown to be as accurate as that of traditional central laboratory PT determinations, to improve the amount of time patients are within the therapeutic INR range, and to decrease the incidence of adverse events associated with anticoagulant therapy.
引用
收藏
页码:25 / 28
页数:3
相关论文
共 74 条
[11]  
Wintzen AR(1989)Home prothrombin time monitoring after the initiation of warfarin therapy. A randomized, prospective study Ann Intern Med 111 730-732
[12]  
van der Meer FJ(1995)Long-term patient self-management of oral anticoagulation Arch Intern Med 155 2185-1867
[13]  
Vandenbroucke JP(1996)Membrane-based, dry-reagent prothrombin time tests Biomed Instrume Technol 30 245-210
[14]  
Briet E.(1995)Multicenter evaluation of a new capillary blood prothrombin time monitoring system Blood Coagul Fibrinolysis 6 726-592
[15]  
Hylek EM(1997)Multicenter trial of accurate home self-testing in oral anticoagulant patients with a novel whole blood system (abstr) J Am Coil Cordiol 29 525-undefined
[16]  
Skates SJ(1995)Accuracy of laboratory and portable monitor international normalized ratio determinations. Comparison with a criterion standard Arch Intern Med 155 1861-undefined
[17]  
Sheehan MA(1994)Outpatient use of a portable international normalized ratio/prothrombin time monitor South Med J 87 206-undefined
[18]  
Singer DE.(1992)Accuracy and precision of a portable anticoagulation monitor in a clinical setting Arch Intern Med 152 589-undefined
[19]  
Singer DE(undefined)undefined undefined undefined undefined-undefined
[20]  
Hylek EM.(undefined)undefined undefined undefined undefined-undefined