Experimental study of indoor and outdoor airborne bacterial concentrations in Tempe, Arizona, USA

被引:55
作者
Hong Zhu
Patrick E. Phelan
Tianhua Duan
Gregory B. Raupp
Harindra J.S. Fernando
Fengxiang Che
机构
[1] Beijing Inst. Microbiol./Epidemiol.
[2] Dept. of Mechanical and Aerosp. Eng., Arizona State University, Tempe, AZ 85287-6106
关键词
Airborne bacteria; Concentration; Indoor-outdoor; USA;
D O I
10.1023/B:AERO.0000006571.23160.8a
中图分类号
学科分类号
摘要
Indoor and outdoor airborne bacterial concentrations were examined in an occupied office building equipped with an air conditioning (HVAC) system, in Tempe, Arizona, USA. A two-stage microbial air sampler was used to collect bacteria both inside and outside the office at fixed locations in space, and at regular time intervals from August to December, 2000. Simultaneous measurement of bacterial concentrations, temperature, relative humidity, light intensity and wind speed were performed to explore the effects of environmental factors on bacteria levels. Ten genera and twenty species of airborne bacteria were found in our samples. Airborne Gram-positive bacteria were most abundant, with more than 90% of the measured population. The particle sizes of most outdoor and indoor airborne bacterial aerosols were larger than 8.0 μm. According to the measurements of either a typical day or three consecutive days, the concentrations of outdoor airborne bacteria were highest in the morning, but declined in the afternoon and reached the lowest point in the evening. With regard to the effects of four environmental factors - temperature, relative humidity, light intensity, and wind speed, the relative humidity had the most pronounced influence on the outdoor bacterial concentration, with the number of bacteria increasing sharply on a day of high relative humidity.
引用
收藏
页码:201 / 211
页数:10
相关论文
共 28 条
[11]  
Holt J.G., Krieg N.R., Sneath P.H.A., Staley J.T., Williams S.T., Bergey's Manual of Determinative Bacteriology (9th Edition), (1994)
[12]  
Kodama A.M., McGee R.I., Airborne microbial contaminants in indoor environments. Naturally ventilated and air conditioned homes, Arch. Environ. Health, 41, pp. 306-311, (1986)
[13]  
Lighthart B., Bacterial flux from chaparral into the atmosphere in mid-summer at a high desert location, Atmospheric Environment, 28, pp. 1267-1274, (1994)
[14]  
Lundholm M., Comparison of methods for quantitative determination of airborne bacteria and evaluation of total viable counts, Appl. Environ. Microbiol., 44, pp. 179-183, (1982)
[15]  
Marcinelli R.L., Et al., Airborne bacteria in an urban environment, Appl. Environ. Microbiol., 35, pp. 1095-1101, (1978)
[16]  
Miller J.D., Et al., Fungi as contaminants in indoor air, Atmospheric Environment, 26 A, pp. 2163-2172, (1992)
[17]  
(2000)
[18]  
Okuyama K., Kousaka Y., Yamamoto S., Hosokawa T., Particle loss of aerosols with particle diameters between 6 and 2000 nm in stirred tank, Journal of Colloid and Interface Science, 110, pp. 214-223, (1986)
[19]  
Owen M.K., Ensor D.S., Sparks L.E., Airborne particle sizes and sources found in indoor air, Atmospheric Envir., 26, pp. 2149-2162, (1992)
[20]  
Ping R., Jankun T.M., Leaderer B.P., Comparisons of seasonal fungal prevalence in indoor and outdoor air and house dusts of dwellings in one Northeast American county, Journal of Exposure Analysis and Environmental Epidemiology, 9, pp. 560-568, (1999)