摘要
Purpose. The authors sought to compare the sensitivity and reading time obtained using computer-aided detection (CAD) software as second reader (SR) or concurrent reader (CR) in the identification of pulmonary nodules. Materials and methods. Unenhanced CT scans of 100 consecutive cancer patients were retrospectively reviewed by four readers to identify all solid, noncalcified pulmonary nodules ranging from 3 to 30 mm in diameter. The sensitivity and reading time of each reader and of CAD alone were calculated at 3-mm and 5-mm thresholds with respect to the reference standard, consisting of a consensus reading by the four radiologists involved in the study. The McNemar test was used to compare the sensitivities obtained by reading without CAD (readers 1 and 2), with CAD as SR (readers 1 and 2 with a 2-month delay), and with CAD as CR (readers 3 and 4). The paired Student's t test was used to compare reading times. A value of p<0.05 was considered statistically significant. Results. A total of 258 and 224 nodules were identified at 3-mm and 5-mm thresholds, respectively. The sensitivity of CAD alone was 62.79% and 67.41% at the 3-mm and 5-mm threshold values respectively, with 4.15 and 2.96 false-positive findings per examination. CAD as SR produced a significant increase in sensitivity (p<0.001) in nodule detection with respect to reading without CAD both at 3 mm (12.01%) and 5 mm (10.04%); the average increase in sensitivity obtained when comparing CAD as SR to CAD as CR was statistically significant (p<0.025) both at the 3-mm (5.35%) and 5-mm (4.68%) thresholds. CAD as CR produced a nonsignificant increase in sensitivity compared with reading without CAD (p>0.05). Mean reading time using CAD as SR (330 s) was significantly longer than reading without CAD (135 s, p<0.001) and reading with CAD as CR (195 s, p<0.025). Conclusions. The use of CAD as CR, without any significant increase in reading time, produces no significant increase in sensitivity in pulmonary nodule detection when compared with reading without CAD (p>0.05); CAD as SR, at the cost of longer reading times, increases sensitivity when compared with reading without CAD (p<0.001) or with CAD as CR (p<0.025).
引用
收藏
页码:950 / 961
页数:12
相关论文
共 36 条
[1]
Multi Slice Computed Tomography in the study of pulmonary metastases [J].
Angelelli, G. ;
Grimaldi, V. ;
Spinelli, F. ;
Scardapane, A. ;
Sardaro, A. .
RADIOLOGIA MEDICA, 2008, 113 (07) :954-967
[2]
Assessment of Radiologist Performance in the Detection of Lung Nodules: Dependence on the Definition of "Truth" [J].
Armato, Samuel G., III ;
Roberts, Rachael Y. ;
Kocherginsky, Masha ;
Aberle, Denise R. ;
Kazerooni, Ella A. ;
MacMahon, Heber ;
van Beek, Edwin J. R. ;
Yankelevitz, David ;
McLennan, Geoffrey ;
McNitt-Gray, Michael F. ;
Meyer, Charles R. ;
Reeves, Anthony P. ;
Caligiuri, Philip ;
Quint, Leslie E. ;
Sundaram, Baskaran ;
Croft, Barbara Y. ;
Clarke, Laurence P. .
ACADEMIC RADIOLOGY, 2009, 16 (01) :28-38
[3]
Computerized detection of pulmonary nodules on CT scans [J].
Armato, SG ;
Giger, ML ;
Moran, CJ ;
Blackburn, JT ;
Doi, K ;
MacMahon, H .
RADIOGRAPHICS, 1999, 19 (05) :1303-1311
[4]
Lung cancer: Performance of automated lung nodule detection applied to cancers missed in a CT screening program [J].
Armato, SG ;
Li, F ;
Giger, ML ;
MacMahon, H ;
Sone, S ;
Doi, K .
RADIOLOGY, 2002, 225 (03) :685-692
[5]
Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[6]
Computer-aided detection of solid lung nodules on follow-up MDCT screening: Evaluation of detection, tracking, and reading time [J].
Beigelman-Aubrey, Catherine ;
Raffy, Philippe ;
Yang, Wenjie ;
Castellino, Ronald A. ;
Grenier, Philippe A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (04) :948-955
[7]
Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader [J].
F. Beyer ;
L. Zierott ;
E. M. Fallenberg ;
K. U. Juergens ;
J. Stoeckel ;
W. Heindel ;
D. Wormanns .
European Radiology, 2007, 17 (11) :2941-2947
[8]
PULMONARY NODULES - EFFECT OF INCREASED DATA SAMPLING ON DETECTION WITH SPIRAL CT AND CONFIDENCE IN DIAGNOSIS [J].
BUCKLEY, JA ;
SCOTT, WW ;
SIEGELMAN, SS ;
KUHLMAN, JE ;
URBAN, BA ;
BLUEMKE, DA ;
FISHMAN, EK .
RADIOLOGY, 1995, 196 (02) :395-400
[9]
Performance evaluation of a computer-aided detection algorithm for solid pulmonary nodules in low-dose and standard-dose MDCT chest examinations and its influence on radiologists [J].
Das, M. ;
Muehlenbruch, G. ;
Heinen, S. ;
Mahnken, A. H. ;
Salganicoff, M. ;
Stanzel, S. ;
Guenther, R. W. ;
Wildberger, J. E. .
BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (971) :841-847
[10]
Current status and future potential of computer-aided diagnosis in medical imaging [J].
Doi, K .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 :S3-S19