Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment

被引:56
作者
Paweł Petkow Dimitrow
机构
[1] 2nd Department of Cardiology CMUJ,
关键词
coronary flow reserve; transthoracic Doppler echocardiography;
D O I
10.1186/1476-7120-1-4
中图分类号
学科分类号
摘要
This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR) in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery). Post-stenotic CFR measurement is helpful in: functional assessment of moderate stenosis, detection of significant or critical stenosis, monitoring of restenosis after revascularization. In the absence of stenosis in the epicardial coronary artery, decreased CFR enable to detect impaired microvascular vasodilatation in: reperfused myocardial infarct, arterial hypertension with or without left ventricular hypertrophy, diabetes mellitus, hypercholesterolemia, syndrome X, hypertrophic cardiomyopathy. In these diseases, noninvasive transthoracic Doppler echocardiography allows for serial CFR evaluations to explore the effect of various pharmacological therapies.
引用
收藏
相关论文
共 323 条
[31]  
Zedda N(2000)Physiologically guided angioplasty in support to a provisional stenting strategy: immediate and six-month outcome Catheter Cardiovasc Interv 49 369-375
[32]  
Montisci R(1997)Prognostic value of intracoronary flow velocity and diameter stenosis in assessing the stenosis in assessing the short- and long-term outcomes of coronary balloon angioplasty; the DEBATE study Circulation 96 3369-3377
[33]  
Ruscazio M(1999)Abnormal coronary flow velocity reserve after coronary stenting in patients: role of relative coronary reserve to assess potential mechanisms Circulation 100 2491-2498
[34]  
Lai G(1998)Immediate and long-term effect of balloon angioplasty or stent implantation on the absolute and relative coronary blood flow velocity reserve Circulation 98 2133-2140
[35]  
Cadeddu M(1999)Hyperemic coronary flow after optimized intravascular ultrasound-guided balloon angioplasty and stent implantation J Am Coll Cardiol 34 1899-1906
[36]  
Meloni L(2003)Noninvasive coronary flow reserve assessed by transthoracic coronary Doppler ultrasound in patients with left anterior descending coronary artery stents Am J Cardiol 91 522-526
[37]  
Iliceto S(2002)Detection of coronary restenosis after coronary angioplasty by contrast-enhanced transthoracic echocardiographic Doppler assessment of coronary flow velocity reserve J Am Coll Cardiol 40 896-903
[38]  
Caiati C(2000)Value of acceleration flow and the prestenotic to stenotic coronary flow velocity ratio by transthoracic color Doppler echocardiography in noninvasive diagnosis of restenosis after percutaneous transluminal coronary angioplasty J Am Coll Cardiol 35 164-168
[39]  
Zedda N(2000)Technical achievement: transthoracic Doppler echocardiography can be used to detect LAD restenosis after coronary angioplasty Clin Physiol 20 428-433
[40]  
Montaldo C(2002)Can coronary flow velocity reserve determined by transthoracic Doppler echocardiography predict the recovery of regional left ventricular function in patients with acute myocardial infarction? Heart 88 137-141