2 SYSTEMS FOR THE AUTOMATED-ANALYSIS OF DRUGS IN BIOLOGICAL-FLUIDS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:15
作者
DOYLE, E
MCDOWALL, RD
MURKITT, GS
PICOT, VS
ROGERS, SJ
机构
[1] Department of Drug Analysis, Smith Kline and French Research Ltd., Welwyn, Hertfordshire AL6 9AR, The Frythe
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1990年 / 527卷 / 01期
关键词
D O I
10.1016/S0378-4347(00)82084-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes two fully automated assays. One for zaprinast, a cGMP specific phosphodiesterase inhibitor, which uses the Gilson-Advanced Automated Sample Processor combination, and the other for an H+/K+ ATPase inhibitor and its sulphone metabolite, which uses direct injection. Both assays were developed to support pharmacokinetic studies at therapeutic doses in small animals as well as in man. Plasma or serum (20-200 μl) is placed directly into an autosampler and all subsequent manipulations are performed mechanically. © 1990.
引用
收藏
页码:67 / 77
页数:11
相关论文
共 13 条
[1]   ANALYSIS OF DRUGS FROM BIOLOGICAL-FLUIDS USING DISPOSABLE SOLID-PHASE COLUMNS [J].
DOYLE, E ;
PEARCE, JC ;
PICOT, VS ;
LEE, RM .
JOURNAL OF CHROMATOGRAPHY, 1987, 411 :325-333
[2]   ONLINE HIGH-PERFORMANCE LIQUID AFFINITY-CHROMATOGRAPHY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ANALYSIS OF MONOMERIC RIBONUCLEOSIDE COMPOUNDS IN BIOLOGICAL-FLUIDS [J].
HAGEMEIER, E ;
KEMPER, K ;
BOOS, KS ;
SCHLIMME, E .
JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC) :663-669
[3]  
HUBER R, IN PRESS J CHROMATOG
[4]  
HUBER R, 1988, SELECTIVE SAMPLE H A, P81
[5]   PRE-COLUMNS OF AMBERLITE XAD-2 FOR DIRECT INJECTION LIQUID-CHROMATOGRAPHIC DETERMINATION OF METHAQUALONE IN BLOOD-PLASMA [J].
HUX, RA ;
MOHAMMED, HY ;
CANTWELL, FF .
ANALYTICAL CHEMISTRY, 1982, 54 (01) :113-117
[6]   QUANTIFICATION OF A POSITIVE INOTROPIC AGENT IN PLASMA - TOWARDS TOTAL AUTOMATION [J].
MURKITT, GS ;
PEARCE, JC ;
MCDOWALL, RD .
CHROMATOGRAPHIA, 1987, 24 :411-415
[7]   SURFACE SILANOLS IN SILICA-BONDED HYDROCARBONACEOUS STATIONARY PHASES .1. DUAL RETENTION MECHANISM IN REVERSED-PHASE CHROMATOGRAPHY [J].
NAHUM, A ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :53-63
[8]   MEASUREMENT OF CONCENTRATIONS OF A NEW H-2-RECEPTOR ANTAGONIST (SK-AND-F 93574) IN PLASMA, URINE AND BILE [J].
PICOT, VS ;
DOYLE, E ;
READ, LJ ;
LEE, RM .
CHROMATOGRAPHIA, 1987, 24 :282-286
[9]  
PICOT VS, IN PRESS J CHROMATOG
[10]   FULLY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - A NEW CHROMATOGRAPH FOR PHARMACOKINETIC DRUG-MONITORING BY DIRECT INJECTION OF BODY-FLUIDS [J].
ROTH, W ;
BESCHKE, K ;
JAUCH, R ;
ZIMMER, A ;
KOSS, FW .
JOURNAL OF CHROMATOGRAPHY, 1981, 222 (01) :13-22