INTERLABORATORY APPLICABILITY OF A RETENTION INDEX LIBRARY OF DRUGS FOR SCREENING BY REVERSED-PHASE HPLC IN SYSTEMATIC TOXICOLOGICAL ANALYSIS

被引:19
作者
BOGUSZ, M [1 ]
ERKENS, M [1 ]
FRANKE, JP [1 ]
WIJSBEEK, J [1 ]
DEZEEUW, RA [1 ]
机构
[1] UNIV GRONINGEN,CTR PHARM,9713 AW GRONINGEN,NETHERLANDS
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1993年 / 16卷 / 06期
关键词
D O I
10.1080/10826079308020957
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The retention indices (RI) of 47 selected acidic, neutral and basic drugs were determined on 7 reversed-phase (octyl- and octadecylsilica) columns in two laboratories in the 1-nitroalkane scale, using either 1-nitroalkane homologues or selected drugs, whose RI values were previously determined on the reference column. Obtained values were compared with the library values, determined previously on the reference column. Retention indices, calculated with drugs as RI markers, showed distinctly lower deviations from the library values and lower inter-column variability: The mean standard deviation of RI for all drugs analyzed on all columns in the 1-nitroalkane scale was 44.3 RI units, against 10.3 units when selected drugs were used as RI markers. The deviations from the listed values, calculated for each column separately with drugs as markers, were in 95% of cases smaller than 20 RI units, and in 80 % smaller than 10 units. The largest differences between the experimental and listed values were observed for column that differed in type of silica support, type of stationary phase (C8 versus C18) or column length in comparison to the reference column. The kind of silica support contributed more to the variability than the type of stationary phase. The results indicate that it is possible to use and exchange HPLC data based on a retention index library.
引用
收藏
页码:1341 / 1354
页数:14
相关论文
共 39 条
[21]   A COLLABORATIVE STUDY TO INVESTIGATE THE RETENTION REPRODUCIBILITY OF BARBITURATES IN HPLC WITH A VIEW TO ESTABLISHING RETENTION DATABASES FOR DRUG IDENTIFICATION [J].
GILL, R ;
MOFFAT, AC ;
SMITH, RM ;
HURDLEY, TG .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (04) :153-159
[22]  
GILL R, 1987, J CHROMATOGR, V386, P65
[23]   COMPARISON OF COLUMNS FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
GOLDBERG, AP .
ANALYTICAL CHEMISTRY, 1982, 54 (02) :342-345
[24]   HPLC PHOTODIODE ARRAY UV DETECTION FOR TOXICOLOGICAL DRUG ANALYSIS [J].
HILL, DW ;
LANGNER, KJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (2-3) :377-409
[25]   AUTOMATED IDENTIFICATION OF TOXIC-SUBSTANCES IN POISONED HUMAN FLUIDS BY A RETENTION PREDICTION SYSTEM IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
JINNO, K ;
KUWAJIMA, M ;
HAYASHIDA, M ;
WATANABE, T ;
HONDO, T .
JOURNAL OF CHROMATOGRAPHY, 1988, 436 (01) :11-21
[26]   RAPID METHOD FOR SCREENING TOXIC DRUGS IN SERUM WITH LIQUID-CHROMATOGRAPHY [J].
KABRA, PM ;
STAFFORD, BE ;
MARTON, LJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1981, 5 (04) :177-182
[27]  
Kaferstein H, 1986, Beitr Gerichtl Med, V44, P253
[29]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY RETENTION DATA FOR 84 BASIC DRUGS OF FORENSIC INTEREST ON A SILICA COLUMN USING AN AQUEOUS METHANOL ELUENT [J].
LAW, B ;
GILL, R ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1984, 301 (01) :165-172
[30]  
LEACH DC, 1988, LC GC EUR, V1, P22