CAPILLARY ELECTROCHROMATOGRAPHY - ANALYSIS OF POLYCYCLIC AROMATIC-HYDROCARBONS

被引:235
作者
YAN, C
DADOO, R
ZHAO, H
ZARE, RN
RAKESTRAW, DJ
机构
[1] STANFORD UNIV,DEPT CHEM,STANFORD,CA 94305
[2] SANDIA NATL LABS,LIVERMORE,CA 94551
关键词
D O I
10.1021/ac00109a020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochromatography is utilized to separate a mixture of 16 different polycyclic aromatic hydrocarbons (PAHs). Fused-silica capillary columns ranging in size from 50 to 150 mu m i.d. were packed (20-40-cm sections) with 3-mu m octadecylsilica particles. A potential of 15-30 kV is applied across the 30-50-cm total length capillary column to generate electroosmotic now that carries the PAHs through the stationary phase. An intracavity-doubled argon ion laser operating at 257 nm is used to detect the PAHs by laser-induced fluorescence. Efficiencies up to 400 000 theoretical plates/m are obtained when detection is performed within the column packing and up to 150 000 theoretical plates/m when detection is performed following a frit (used to hold the packing). The reproducibility of the peak retention times is better than 2% (RSD). The limits of detection for individual PAHs range between 10(-17) and 10(-20) mol(10(-9)-10(-11) M), With a linear response spanning 4 orders of magnitude in concentration.
引用
收藏
页码:2026 / 2029
页数:4
相关论文
共 11 条
[1]   HIGH-RESOLUTION SEPARATIONS BASED ON ELECTROPHORESIS AND ELECTROOSMOSIS [J].
JORGENSON, JW ;
LUKACS, KD .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :209-216
[2]   ELECTROCHROMATOGRAPHY IN PACKED TUBES USING 1.5 TO 50 MU-M SILICA-GELS AND ODS BONDED SILICA-GELS [J].
KNOX, JH ;
GRANT, IH .
CHROMATOGRAPHIA, 1991, 32 (7-8) :317-328
[3]   ULTRASENSITIVE FLUORESCENCE DETECTION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN CAPILLARY ELECTROPHORESIS [J].
NIE, SM ;
DADOO, R ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3571-3575
[4]   ELCTRO-OSMOSIS - NEW CONCEPT FOR HIGH-SPEED LIQUID-CHROMATOGRAPHY [J].
PRETORIUS, V ;
HOPKINS, BJ ;
SCHIEKE, JD .
JOURNAL OF CHROMATOGRAPHY, 1974, 99 (NOV6) :23-30
[5]   THE ANALYSIS OF PHARMACEUTICAL COMPOUNDS USING ELECTROCHROMATOGRAPHY [J].
SMITH, NW ;
EVANS, MB .
CHROMATOGRAPHIA, 1994, 38 (9-10) :649-657
[6]   CYCLODEXTRIN-MODIFIED MICELLAR ELECTROKINETIC CHROMATOGRAPHY - SEPARATION OF HYDROPHOBIC AND ENANTIOMERIC COMPOUNDS [J].
TERABE, S ;
MIYASHITA, Y ;
ISHIHAMA, Y ;
SHIBATA, O .
JOURNAL OF CHROMATOGRAPHY, 1993, 636 (01) :47-55
[7]  
TERABE S, 1984, ANAL CHEM, V56, P113
[8]  
TSUDA T, 1982, J CHROMATOGR, V248, P241, DOI 10.1016/S0021-9673(00)87275-1
[9]  
Weinberger R., 1993, PRACTICAL CAPILLARY
[10]   ELECTROCHROMATOGRAPHY AND MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH 320-MU-M ID PACKED-COLUMNS [J].
YAN, C ;
SCHAUFELBERGER, D ;
ERNI, F .
JOURNAL OF CHROMATOGRAPHY A, 1994, 670 (1-2) :15-23