CALIBRATION OF PARALLEL-PLATE CHAMBERS - RESOLUTION OF SEVERAL PROBLEMS BY USING MONTE-CARLO CALCULATIONS

被引:33
作者
ROGERS, DWO
机构
[1] Ionizing Radiation Standards, Institute for National Measurement Standards, National Research Council Canada, Ottawa
关键词
D O I
10.1118/1.596915
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For five commonly used parallel-plate ion chambers, Monte Carlo calculations are presented of the wall attenuation and scatter correction factors (K(wall) = A(wall)-1 or k(att)-1) and the correction for nonhomogeneous composition of the chamber (K(comp) or related to k(m)). The chambers ar assumed to have 0.5 g/cm2 buildup caps made of the predominant material in each chamber. These correction factors are needed if air-kerma calibration factors are used to deduce the chamber's cavity-gas calibration factor, N(gas). The scatter from the material around the cavity more than compensates for the attenuation in the front wall and hence K(wall) values are less than unity. The corrections for the nonhomogeneous composition can be significant. Thin collectors or insulators behind the collecting volume can have a major effect because electron backscattering depends strongly on material. The calculations agree well with experimental data and explain previous results that had not been understood. Calculations for different buildup caps predict trends in chamber in-air responses, which go in the opposite direction to the k(m) values for homogeneous chambers of the same materials. It is argued that P(wall), the wall correction factor for photon-beam measurements in-phantom is, to first order, the same correction factor as K(comp), calculated for a buildup cap of the same material as the phantom material and the initial assumption that the wall material is made of the same material. Hence, P(wall) can also be significantly different from unity. Recommended values of k(m)k(att) or the equivalent N(gas)/N(X), and P(wall) (in Co-60 beams) are presented for the 5 chambers. These values treat the Exradin P11, Markus and Holt parallel-plate chambers as homogeneous in construction whereas the values for the NACP and Capintec PS-033 chambers demonstrate that the chambers are distinctly nonhomogeneous.
引用
收藏
页码:889 / 899
页数:11
相关论文
共 35 条
[1]   ON THE CALIBRATION OF PLANE-PARALLEL ION CHAMBERS USING CO-60 BEAMS [J].
ANDREO, P ;
LINDBORG, L ;
MEDIN, J .
MEDICAL PHYSICS, 1991, 18 (02) :326-327
[2]   ON THE CALIBRATION OF PLANE-PARALLEL IONIZATION CHAMBERS FOR ELECTRON-BEAM DOSIMETRY [J].
ANDREO, P ;
RODRIGUES, LN ;
LINDBORG, L ;
KRAEPELIEN, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (05) :1147-1165
[3]  
[Anonymous], 1983, MED PHYS, V10, P741
[4]  
[Anonymous], [No title captured]
[6]   CORRECTION FACTORS FOR THICK-WALLED IONIZATION CHAMBERS IN POINT-SOURCE PHOTON BEAMS [J].
BIELAJEW, AF .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (04) :501-516
[7]   THE MONTE-CARLO SIMULATION OF ION-CHAMBER RESPONSE TO CO-60 - RESOLUTION OF ANOMALIES ASSOCIATED WITH INTERFACES [J].
BIELAJEW, AF ;
ROGERS, DWO ;
NAHUM, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (05) :419-427
[8]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[9]   REPLACEMENT CORRECTION FACTORS FOR ELECTRON MEASUREMENTS WITH A PARALLEL-PLATE CHAMBER [J].
CASSON, H ;
KILEY, JP .
MEDICAL PHYSICS, 1987, 14 (02) :216-217
[10]   TOTAL PERTURBATION CORRECTION FACTOR FOR PTW AND NACP PLANE PARALLEL CHAMBERS IN ELECTRON-BEAMS [J].
CINOS, C ;
LIZUAIN, MC ;
FEBRIAN, MI .
RADIOTHERAPY AND ONCOLOGY, 1991, 21 (02) :135-140