EFFECTIVE DOSE VALUES IN BONE-MINERAL MEASUREMENTS BY PHOTON-ABSORPTIOMETRY AND COMPUTED-TOMOGRAPHY

被引:147
作者
KALENDER, WA
机构
[1] Siemens AG Medizinische Technik, Erlangen, 8520
关键词
BONE MINERAL DENSITY; DUAL-ENERGY X-RAY ABSORPTIOMETRY; COMPUTED TOMOGRAPHY; RADIATION DOSE;
D O I
10.1007/BF01623841
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Abstract: A high degree of uncertainty and irritation predominates in the assessment and comparison of radiation dose values resulting from measurements of bone mineral density of the lumbar spine by photon absorptiometry and X-ray computed tomography. The skin dose values which are usually given in the literature are of limited relevance because the size of the irradiated volumes, the relative sensitivity of the affected organs and the radiation energies are not taken into account. The concept of effective dose, sometimes called whole-body equivalent dose, has to be applied. A detailed analysis results in an effective dose value of about 1-mu-Sv for absorptiometry and about 30-mu-Sv for computed tomography when low kV and mAs values are used. Lateral localizer radiographs, which are necessary for slice selection in CT, mean an additional dose of 30-mu-Sv. Lateral X-ray films of the spine which are frequently taken in combination with absorptiometry result in a dose of 700-mu-Sv or more. The concept of effective dose, the basic data and assumptions used in its assessment and a comparison with other dose burdens (for example the natural background radiation, of typically 2400-mu-Sv per year) are discussed in detail.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 25 条
[12]   PRECISION ERROR IN DUAL-PHOTON ABSORPTIOMETRY RELATED TO SOURCE AGE [J].
ROSS, PD ;
WASNICH, RD ;
VOGEL, JM .
RADIOLOGY, 1988, 166 (02) :523-527
[13]  
SCHMIDT T, 1988, Roentgen-Blaetter, V41, P444
[14]   A METHOD FOR DESCRIBING THE DOSES DELIVERED BY TRANSMISSION-X-RAY COMPUTED-TOMOGRAPHY [J].
SHOPE, TB ;
GAGNE, RM ;
JOHNSON, GC .
MEDICAL PHYSICS, 1981, 8 (04) :488-495
[15]  
STEIN JA, 1987, RADIOLOGY, V165, P313
[16]  
STEINBACH W R, 1990, Electromedica (English Edition), V58, P66
[17]  
TRAUT H, 1989, FORTSCHR RONTG NEUEN, V151, P487
[18]  
VIRTAMA P, 1960, Ann Med Intern Fenn, V49, P57
[19]  
VOGEL H, 1989, STRAHLENDOSIS STRAHL
[20]  
Williams G., 1985, BESTIMMUNG ORGANDOSE