PROSPECTS FOR USING AN IVEM WITH A FEG FOR IMAGING MACROMOLECULES TOWARDS ATOMIC RESOLUTION

被引:38
作者
ZHOU, ZH [1 ]
CHIU, W [1 ]
机构
[1] BAYLOR COLL MED, W M KECK CTR COMPUTAT BIOL, HOUSTON, TX 77030 USA
关键词
D O I
10.1016/0304-3991(93)90246-T
中图分类号
TH742 [显微镜];
学科分类号
摘要
Specimen preparation and imaging techniques for biological macromolecules have been improved to the point where attention to the electron-optical imaging conditions becomes a significant factor for achieving high resolution. A field emission gun (FEG) can provide an illumination source with a better spatial and temporal coherence suitable for imaging near atomic resolution. Our computational analysis of carbon film images taken between Scherzer focus and 1.1 mum underfocus (20X Scherzer focus) with the Hitachi 200 kV microscope with a cold field emission gun shows detectable contrast beyond 3.5 angstrom resolution. In biological imaging. a large defocus is often used to optimize the low-resolution contrast in order to facilitate the subsequent steps in computer reconstruction. An intermediate-voltage electron microscope (IVEM) would optimize the contrast at high resolution by reducing the temporal coherent effects. In theory, the IVEM would give a greater depth of field so that large macromolecular assemblies such as viruses and cellular structures can be interpreted and reconstructed reliably using the projection approximation. These experimental and theoretical considerations provide a rationale for designing a future IVEM with a FEG suitable for biological macromolecule imaging close to atomic resolution.
引用
收藏
页码:407 / 416
页数:10
相关论文
共 51 条
[1]   LIQUID-CRYSTALLINE, PHAGE-LIKE PACKING OF ENCAPSIDATED DNA IN HERPES-SIMPLEX VIRUS [J].
BOOY, FP ;
NEWCOMB, WW ;
TRUS, BL ;
BROWN, JC ;
BAKER, TS ;
STEVEN, AC .
CELL, 1991, 64 (05) :1007-1015
[2]   COMPUTER-CONTROLLED SPOT-SCAN IMAGING OF CROTOXIN COMPLEX-CRYSTALS WITH 400 KEV ELECTRONS AT NEAR-ATOMIC RESOLUTION [J].
BRINK, J ;
CHIU, W ;
DOUGHERTY, M .
ULTRAMICROSCOPY, 1992, 46 (1-4) :229-240
[3]   CONTRAST ANALYSIS OF CRYO-IMAGES OF N-PARAFFIN RECORDED AT 400 KV OUT TO 2.1 A RESOLUTION [J].
BRINK, J ;
CHIU, W .
JOURNAL OF MICROSCOPY, 1991, 161 :279-295
[4]   HIGH-RESOLUTION SPOT-SCAN ELECTRON-MICROSCOPY OF MICROCRYSTALS OF AN ALPHA-HELICAL COILED-COIL PROTEIN [J].
BULLOUGH, PA ;
TULLOCH, PA .
JOURNAL OF MOLECULAR BIOLOGY, 1990, 215 (01) :161-173
[5]   CRYO ELECTRON-MICROSCOPY OF UNSTAINED, UNFIXED RECA CSSDNA COMPLEXES [J].
CHANG, CF ;
RANKERT, DA ;
JENG, TW ;
MORGAN, DG ;
SCHMID, MF ;
CHIU, W .
JOURNAL OF ULTRASTRUCTURE AND MOLECULAR STRUCTURE RESEARCH, 1988, 100 (02) :166-172
[6]   POTENTIAL FOR HIGH-RESOLUTION ELECTRON CRYSTALLOGRAPHY AT INTERMEDIATE HIGH-VOLTAGE [J].
CHIU, W ;
JENG, TW ;
DEGN, LL ;
PRASAD, BVV .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1986, 483 :149-156
[7]  
CHIU W, 1977, ULTRAMICROSCOPY, V2, P207
[8]  
CHIU W, 1992, 50TH P ANN EMSA M, P1054
[9]  
CHIU W, 1978, SCANNING ELECTRON MI, V1, P569