INTRINSIC STABILITY OF SELF-SEALING UNSUTURED CATARACT WOUNDS

被引:6
作者
FRIELING, E
STEINERT, RF
机构
[1] CTR EYE RES,BOSTON,MA
[2] UNIV REGENSBURG,DEPT OPHTHALMOL,W-8400 REGENSBURG,GERMANY
[3] HARVARD UNIV,SCH MED,DEPT OPHTHALMOL,BOSTON,MA 02115
关键词
D O I
10.1001/archopht.1993.01090030101048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Many operative and postoperative factors can influence cataract wound stability and postoperative astigmatism. The final outcome is fundamentally dependent on the intrinsic biomechanical stability of the corneal dome in the presence of the wound. We determined the stability of the central and peripheral cornea with computer-assisted topographic analysis of six freshly enucleated human globes. Self-sealing, unsutured, scleral tunnel wounds 4.0 mm in length were dissected, with widths varying from 1.4 to 6.0 mm. Intraocular pressure was elevated in 5-mm increments from 15 to 40 mm Hg without measurable topographic change in the visual axis or superior cornea. We conclude that these long scleral tunnel wounds do not necessarily destabilize the cornea within the usual range of intraocular pressure. Postoperative-induced astigmatism is therefore due to other operative and postoperative factors. Some of these factors may be identifiable with this model and controlled or eliminated.
引用
收藏
页码:381 / 383
页数:3
相关论文
共 16 条
[1]   EFFECT OF INCISION LENGTH, LOCATION, AND SHAPE ON LOCAL CORNEOSCLERAL DEFORMATION DURING CATARACT-SURGERY [J].
ARMENIADES, CD ;
BORIEK, A ;
KNOLLE, GE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01) :83-87
[2]   COMPARISON OF POSTOPERATIVE ASTIGMATISM WITH INCISIONS OF VARYING LENGTH CLOSED WITH HORIZONTAL SUTURES AND WITH NO SUTURES [J].
BUZARD, KA ;
SHEARING, SP .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 :734-739
[3]   RELATIVE STRENGTH OF CATARACT INCISIONS IN CADAVER EYES [J].
ERNEST, PH ;
KIESSLING, LA ;
LAVERY, KT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 :668-671
[4]   SURGICALLY INDUCED ASTIGMATISM IN HUMAN CADAVER EYES [J].
FLAHARTY, PM ;
SIEPSER, SB .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (01) :19-24
[5]   EARLY RESULTS OF 500 CASES OF NO-STITCH CATARACT-SURGERY [J].
GRABOW, HB .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 :726-730
[6]   ACCURACY AND PRECISION OF KERATOMETRY, PHOTOKERATOSCOPY, AND CORNEAL MODELING ON CALIBRATED STEEL BALLS [J].
HANNUSH, SB ;
CRAWFORD, SL ;
WARING, GO ;
GEMMILL, MC ;
LYNN, MJ ;
NIZAM, A .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (08) :1235-1239
[7]   SCLERAL FLAP SURGERY FOR MODIFICATION OF CORNEAL ASTIGMATISM [J].
KOCH, DD ;
DELPERO, RA ;
WONG, TC ;
MCCULLOCH, RR ;
WEAVER, TA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1987, 104 (03) :259-264
[8]   STRUCTURAL-ANALYSIS OF CATARACT INCISION CONSTRUCTION [J].
KOCH, PS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 :661-667