RADIATION-RESISTANCE OF MICROORGANISMS ON UNSTERILIZED INFUSION SETS

被引:2
作者
CHRISTENSEN, EA
KRISTENSEN, H
HOBORN, J
MILLER, A
机构
[1] RISO NATL LAB,DEPT ACCELERATOR,DK-4000 ROSKILDE,DENMARK
[2] MOLNLYCKE HLTH CARE AB,GOTHENBURG,SWEDEN
关键词
RADIATION RESISTANCE; STERILIZATION; MEDICAL DEVICE; DEINOCOCCUS-RADIODURANS;
D O I
10.1111/j.1699-0463.1991.tb01236.x
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Three different methods were used for detecting and isolating microorganisms with high radiation resistance from the microbial contamination on infusion sets prior to sterilization. By all three methods, microorganisms with a radiation resistance high enough to be a critical factor in a sterilization process (D-6 value greater-than-or-equal-to 30 kGy) were found with a frequency of approximately two colony forming units (cfu) per 100 product items, even though the product items in two of the series of analyses were irradiated with doses of 3-6 kGy. The frequency of occurrence of isolates with D-6 values greater-than-or-equal-to 30 kGy was 0.45 per 1000 cfu of the total aerobic count. Eight different isolates of microorganisms had D-6 values greater-than-or-equal-to 40 kGy when irradiated in dried laboratory preparation. All but one of these were classified according to morphologic criteria as Deinococcus, and all but one had nonlinear dose-response relationships in semilogarithmic presentation.
引用
收藏
页码:620 / 626
页数:7
相关论文
共 13 条
[1]  
[Anonymous], 1983, EUROPEAN PHARMACOPOE
[2]  
ARTANDI C, 1973, MANUAL RAD STERILIZA, P171
[3]  
BJERGBAKKE E, 1973, RISO M1651 ACC DEP N
[4]  
CHRISTENSEN EA, 1981, ACTA PATH MICRO IM B, V89, P293
[5]  
CHRISTENSEN EA, 1974, EXPERIENCES RAD STER, P67
[6]   THE RATIONALE AND A COMPUTER EVALUATION OF A GAMMA-IRRADIATION STERILIZATION DOSE DETERMINATION METHOD FOR MEDICAL DEVICES USING A SUBSTERILIZATION INCREMENTAL DOSE STERILITY TEST PROTOCOL [J].
DAVIS, KW ;
STRAWDERMAN, WE ;
WHITBY, JL .
JOURNAL OF APPLIED BACTERIOLOGY, 1984, 57 (01) :31-50
[7]   SIMPLIFIED STATISTICS FOR SMALL NUMBERS OF OBSERVATIONS [J].
DEAN, RB ;
DIXON, WJ .
ANALYTICAL CHEMISTRY, 1951, 23 (04) :636-638
[8]  
DOOLAN PT, 1988, RADIAT PHYS CHEM, V31, P699
[9]  
MILLER A, 1988, RADIAT PHYS CHEM, V31, P491
[10]   MICROBIOLOGICAL QUALITY CONTROL OF STERILIZED PRODUCTS - EVALUATION OF A MODEL RELATING FREQUENCY OF CONTAMINATED ITEMS WITH INCREASING RADIATION TREATMENT [J].
TALLENTIRE, A ;
DWYER, J ;
LEY, FJ .
JOURNAL OF APPLIED BACTERIOLOGY, 1971, 34 (03) :521-+