NOVEL FLOW-INJECTION ANALYSIS SYSTEMS FOR DRUG ANALYSIS

被引:13
作者
CHRISTIAN, GD
机构
[1] Department of Chemistry/BG-10, University of Washington, Seattle
关键词
D O I
10.1016/0731-7085(91)80078-N
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection analysis (FIA) has become a versatile tool for rapid and automate analyses. As its capabilities have increased, so have the complexity and operation of the apparatus. We have been investigating ways to simplify both the apparatus and the application of injection techniques. A novel cam-driven syringe pump and the development of sequential injection analysis (SIA) are reviewed, and some applications presented. Flow injection coulometric titrations are presented as a means to further alleviate reagent stability and calibration problems. These systems have potential for automatically carrying out many drug assays. 23180 A flow injection analysis (FIA) procedure is described for the determination of chlorocresol in a parenteral pharmaceutical formulation. The product is directly injected into a carrier stream of water and subsequently reacted with a reagent stream of nitrous acid. The resulting brown nitro-derivative is determined spectrophotometrically at 400 nm. The method has been validated and should be applicable to chlorocresol in other pharmaceutical products and to compounds containing a phenolic ring, assuming absence of matrix interference.
引用
收藏
页码:769 / 773
页数:5
相关论文
共 32 条
[1]  
ABBOTT R W, 1986, Analytical Proceedings, V23, P25
[2]   APPLICATION OF GRADIENT FLOW-INJECTION ANALYSIS TO STUDIES OF DRUG - PROTEIN-BINDING [J].
ABDULLAHI, GL ;
MILLER, JN .
ANALYST, 1985, 110 (10) :1271-1272
[3]   STUDIES OF DRUG PROTEIN-BINDING INTERACTIONS BY FLOW-INJECTION ANALYSIS WITH FLUORIMETRIC DETECTION [J].
ABDULLAHI, GL ;
MILLER, JN ;
STURLEY, HN ;
BRIDGES, JW .
ANALYTICA CHIMICA ACTA, 1983, 145 (JAN) :109-116
[4]   CHEMILUMINESCENCE DETERMINATION OF BUPRENORPHINE HYDROCHLORIDE BY FLOW-INJECTION ANALYSIS [J].
ALWARTHAN, AA ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1986, 185 :329-333
[5]   AUTOMATED FLOW-INJECTION PHENOL RED METHOD FOR DETERMINATION OF BROMIDE AND BROMIDE SALTS IN DRUGS [J].
ANAGNOSTOPOULOU, PI ;
KOUPPARIS, MA .
ANALYTICAL CHEMISTRY, 1986, 58 (02) :322-326
[6]   CONTINUOUS SOLVENT-EXTRACTION IN A CLOSED-LOOP SYSTEM [J].
ATALLAH, RH ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :2909-2914
[7]   FLOW-INJECTION ANALYSIS OF 3 N-SUBSTITUTED PHENOTHIAZINE DRUGS WITH AMPEROMETRIC DETECTION AT A CARBON-FIBER ARRAY ELECTRODE [J].
BELAL, F ;
ANDERSON, JL .
ANALYST, 1985, 110 (12) :1493-1496
[8]   DETERMINATION OF LEVAMISOLE HYDROCHLORIDE WITH HGI(4)2- BY A TURBIDIMETRIC METHOD AND FLOW-INJECTION ANALYSIS [J].
CALATAYUD, JM ;
FALCO, C .
TALANTA, 1986, 33 (08) :685-687
[9]   VOLTAMMETRIC DETERMINATION OF DOXORUBICIN IN URINE BY ADSORPTIVE PRECONCENTRATION AND FLOW-INJECTION ANALYSIS [J].
CHANEY, EN ;
BALDWIN, RP .
ANALYTICA CHIMICA ACTA, 1985, 176 (OCT) :105-112
[10]  
CHRISTIAN GD, 1986, INSTRUMENTAL ANAL, P98