HEMOSTATIC PROTEIN POLYMER SHEATH - IMPROVEMENT IN HEMOSTASIS AT PERCUTANEOUS BIOPSY IN THE SETTING OF PLATELET DYSFUNCTION

被引:4
作者
GAZELLE, GS [1 ]
HAAGA, JR [1 ]
HALPERN, EF [1 ]
机构
[1] CASE WESTERN RESERVE UNIV HOSP,DEPT RADIOL,CLEVELAND,OH 44106
关键词
BIOPSIES; COMPLICATIONS; TECHNOLOGY; INTERVENTIONAL PROCEDURES; LIVER; HEMORRHAGE; INTERVENTIONAL PROCEDURE;
D O I
10.1148/radiology.187.1.8451426
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
To study the effectiveness of the protein polymer sheath (PPS), a device intended to limit hemorrhage caused by percutaneous biopsy, in the setting of platelet dysfunction (which may be an important cause of such hemorrhage), percutaneous biopsies were performed in eight anesthetized pigs: four control pigs and four pigs treated with the experimental aspirinlike drug venopirin. These biopsies were performed with (a) a cutting needle only, (b) the cutting needle equipped with the PPS, and (c) the cutting needle equipped with a thrombin-coated PPS. Needle configuration and biopsy site were randomized. Blood loss associated with each needle configuration was measured and compared with that associated with the other configurations. Venopirin caused a statistically significant increase in blood loss with all needle configurations. The PPS significantly reduced blood loss in both the control pigs and those treated with venopirin (P < .05); thrombin coating was a statistically significant factor only in the venopirin-treated pigs.
引用
收藏
页码:269 / 272
页数:4
相关论文
共 13 条
[1]
PERCUTANEOUS LIVER-BIOPSY AND TRACK EMBOLIZATION WITH STEEL COILS [J].
ALLISON, DJ ;
ADAM, A .
RADIOLOGY, 1988, 169 (01) :261-263
[2]
SHEATH NEEDLE FOR LIVER-BIOPSY IN HIGH-RISK PATIENTS [J].
CHUANG, VP ;
ALSPAUGH, JP .
RADIOLOGY, 1988, 166 (01) :261-262
[3]
A TECHNIQUE FOR EMBOLIZATION OF BIOPSY TRACTS [J].
CRUMMY, AB ;
MCDERMOTT, JC ;
WOJTOWYCZ, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (01) :67-68
[4]
HEMOSTATIC PROTEIN-POLYMER SHEATH - NEW METHOD TO ENHANCE HEMOSTASIS AT PERCUTANEOUS BIOPSY [J].
GAZELLE, GS ;
HAAGA, JR ;
NEUHAUSER, D .
RADIOLOGY, 1990, 175 (03) :671-674
[5]
EFFECT OF NEEDLE GAUGE, LEVEL OF ANTICOAGULATION, AND TARGET ORGAN ON BLEEDING ASSOCIATED WITH ASPIRATION BIOPSY - WORK IN PROGRESS [J].
GAZELLE, GS ;
HAAGA, JR ;
ROWLAND, DY .
RADIOLOGY, 1992, 183 (02) :509-513
[6]
GAZELLE GS, IN PRESS JVIR
[7]
PERRAULT J, 1978, GASTROENTEROLOGY, V74, P103
[8]
DELAYED HEMORRHAGE AFTER PERCUTANEOUS LIVER-BIOPSY [J].
REICHERT, CM ;
WEISENTHAL, LM ;
KLEIN, HG .
JOURNAL OF CLINICAL GASTROENTEROLOGY, 1983, 5 (03) :263-266
[9]
RILEY SA, 1984, LANCET, V2, P436
[10]
PLUGGED LIVER-BIOPSY IN PATIENTS WITH IMPAIRED COAGULATION [J].
TOBIN, MV ;
GILMORE, IT .
DIGESTIVE DISEASES AND SCIENCES, 1989, 34 (01) :13-15