ULTRAVIOLET CONFOCAL FLUORESCENCE MICROSCOPY OF THE INVITRO CORNEA - REDOX METABOLIC IMAGING

被引:35
作者
MASTERS, BR
KRIETE, A
KUKULIES, J
机构
[1] CARL ZEISS AG, DIV APPL MICROSCOPY, W-7802 OBERKOCHEN, GERMANY
[2] UNIV GIESSEN, INST ANAT & CYTOBIOL, W-6300 GIESSEN, GERMANY
来源
APPLIED OPTICS | 1993年 / 32卷 / 04期
关键词
CONFOCAL LASER SCANNING MICROSCOPE; CORNEA; EPITHELIUM; ENDOTHELIUM; REDUCED PYRIDINE NUCLEOTIDES; REDOX FLUOROMETRY;
D O I
10.1364/AO.32.000592
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A laser scanning microscope was fitted with two argon-ion lasers that provided wavelengths in the regions of 364, 488, and 514 nm. A Zeiss water objective of 25x, with a numerical aperture of 0.8, corrected for the UV, was used to measure the fluorescence from optical sections of freshly enucleated rabbit eyes. The confocal microscope was used in both the reflected and fluorescent modes to image in situ epithelial and endothelial cells. An excitation wavelength of 364 nm and emission at 400-500 nm were used to image the fluorescence from reduced pyridine nucleotides. We demonstrate the feasibility of two-dimensional fluorescent confocal imaging of reduced pyridine nucleotides in corneal epithelial and endothelial cells.
引用
收藏
页码:592 / 596
页数:5
相关论文
共 26 条
[1]  
Bennett S. D., 1988, Proceedings of the SPIE - The International Society for Optical Engineering, V897, P75, DOI 10.1117/12.944516
[2]  
CHANCE B, 1959, J BIOL CHEM, V234, P3044
[3]   INTRINSIC FLUORESCENCE EMISSION FROM CORNEA AT LOW-TEMPERATURES - EVIDENCE OF MITOCHONDRIAL SIGNALS AND THEIR DIFFERING REDOX STATES IN EPITHELIAL AND ENDOTHELIAL SIDES [J].
CHANCE, B ;
LIEBERMAN, M .
EXPERIMENTAL EYE RESEARCH, 1978, 26 (01) :111-117
[4]   NICOTINAMIDE ADENINE-DINUCLEOTIDE FLUORESCENCE SPECTROSCOPY AND IMAGING OF ISOLATED CARDIAC MYOCYTES [J].
ENG, J ;
LYNCH, RM ;
BALABAN, RS .
BIOPHYSICAL JOURNAL, 1989, 55 (04) :621-630
[5]   DEEP ULTRAVIOLET MICROSCOPE [J].
HEIMANN, PA ;
URSTADT, R .
APPLIED OPTICS, 1990, 29 (04) :495-501
[6]  
KAPITZA HG, 1988, P SOC PHOTOOPTICAL I, V1028, P173
[7]   DEPTH RESOLUTION OF THE FLUORESCENT CONFOCAL SCANNING OPTICAL MICROSCOPE [J].
KIMURA, S ;
MUNAKATA, C .
APPLIED OPTICS, 1990, 29 (04) :489-494
[8]   CALCULATION OF 3-DIMENSIONAL OPTICAL TRANSFER-FUNCTION FOR A CONFOCAL SCANNING FLUORESCENT MICROSCOPE [J].
KIMURA, S ;
MUNAKATA, C .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1989, 6 (07) :1015-1019
[9]  
KRIETE A, 1990, T ROY MICR, V1, P401
[10]  
Lemp M A, 1985, Cornea, V4, P205