A GLOW-DISCHARGE ION-SOURCE WITH FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRIC DETECTION

被引:32
作者
BARSHICK, CM [1 ]
EYLER, JR [1 ]
机构
[1] UNIV FLORIDA,DEPT CHEM,GAINESVILLE,FL 32611
关键词
D O I
10.1016/1044-0305(92)87045-Z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A glow discharge (GD) ion source has been coupled to a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer using a four-element electrostatic lens to accelerate and focus ions generated external to the instrument's high magnetic field into its analyzer cell. Like other GD mass spectrometers, GD-FT-ICR can provide a quantitative measure of bulk analyte concentration with good precision and accuracy. Although detection limits currently attainable are several orders of magnitude higher than the commercially available magnetic sector-based instrument, GD-FT-ICR holds promise for ultrahigh resolving power elemental mass analysis. Several schemes are proposed to lower the detection limits of the technique while still providing high enough resolution to resolve isobaric interferences.
引用
收藏
页码:122 / 127
页数:6
相关论文
共 41 条
[21]   EXTERNAL GENERATION OF IONS IN ICR SPECTROMETRY [J].
KOFEL, P ;
ALLEMANN, M ;
KELLERHALS, H ;
WANCZEK, KP .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 65 (1-2) :97-103
[22]   A HIGH-PRESSURE EXTERNAL ION-SOURCE FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROMETRY [J].
KOFEL, P ;
MCMAHON, TB .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 98 (01) :1-24
[23]   PRECISE RELATIVE ION ABUNDANCES FROM FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MAGNITUDE-MODE MASS-SPECTRA [J].
LIANG, ZM ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1990, 62 (01) :70-75
[24]   LIMIT OF DETECTION [J].
LONG, GL ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1983, 55 (07) :A712-+
[25]   FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY - THE TEENAGE YEARS [J].
MARSHALL, AG ;
GROSSHANS, PB .
ANALYTICAL CHEMISTRY, 1991, 63 (04) :A215-A229
[26]   LASER DESORPTION FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
MCCRERY, DA ;
LEDFORD, EB ;
GROSS, ML .
ANALYTICAL CHEMISTRY, 1982, 54 (08) :1435-1437
[27]   COUPLING A QUADRUPOLE MASS-SPECTROMETER AND A FOURIER-TRANSFORM MASS-SPECTROMETER [J].
MCIVER, RT ;
HUNTER, RL ;
BOWERS, WD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 64 (01) :67-77
[28]  
RATLIFF PH, 1990, 38TH ASMS C MASS SPE, P1441
[29]   THERMOCHEMICAL INTERPRETATION OF ELECTRODE-POTENTIALS FOR TRANSITION-METAL COMPLEXES [J].
RICHARDSON, DE .
INORGANIC CHEMISTRY, 1990, 29 (17) :3213-3217
[30]   ATTENUATION OF POLYATOMIC ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY BY GAS-PHASE COLLISIONS [J].
ROWAN, JT ;
HOUK, RS .
APPLIED SPECTROSCOPY, 1989, 43 (06) :976-980