METHODOLOGICAL ASPECTS OF BRAIN ACTIVATION STUDIES - CEREBRAL BLOOD-FLOW DETERMINED WITH [O-15]BUTANOL AND POSITRON EMISSION TOMOGRAPHY

被引:46
作者
INGVAR, M
ERIKSSON, L
GREITZ, T
STONEELANDER, S
DAHLBOM, M
ROSENQVIST, G
AFTRAMPE, P
VONEULER, C
机构
[1] KAROLINSKA INST,KAROLINSKA HOSP,DEPT NEURORADIOL,S-10401 STOCKHOLM,SWEDEN
[2] KAROLINSKA INST,KAROLINSKA HOSP,KAROLINSKA PHARM,S-10401 STOCKHOLM,SWEDEN
[3] UNIV STOCKHOLM,DEPT LINGUIST,STOCKHOLM,SWEDEN
[4] KAROLINSKA INST,NOBEL INST NEUROPHYSIOL,S-10401 STOCKHOLM,SWEDEN
[5] UNIV CALIF LOS ANGELES,DEPT RADIOL SCI,DIV NUCL MED & BIOPHYS,LOS ANGELES,CA 90024
关键词
POSITRON EMISSION TOMOGRAPHY; REGIONAL CBF; BRAIN ACTIVATION;
D O I
10.1038/jcbfm.1994.78
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this methodological study, a procedure for measuring regional CBF (rCBF) with positron emission tomography and O-15-labelled tracers is optimized. Four healthy volunteers were subjected to eight studies with use of [O-15]butanol as a tracer: four times while reading aloud and four times while reading silently from a phonologically balanced list of single words. The gain from these repeated intra-individual studies of the same activation state (fractionation) was demonstrated in terms of noise-equivalent counts in a phantom study. A computerized brain atlas was used to reformat the images to a common anatomical representation, thereby minimizing the effects of inter- and intra-individual anatomical and positional variations. This allowed the formation of inter and intra-individual average subtraction images with error estimates. Differences between the two activation states were detected with use of an exploratory significance map based on a paired Student's t test. The results compared well with Friston's method of determining levels of statistical significance. No difference was obtained when comparing results from rCBF images and images generated from measurement of uptake of the tracer. The paradigm chosen for activation was shown to yield a constant activation level during the repeated measurements (i.e., no habituation).
引用
收藏
页码:628 / 638
页数:11
相关论文
共 44 条
[1]   HEAD FIXATION DEVICE FOR REPRODUCIBLE POSITION ALIGNMENT IN TRANSMISSION CT AND POSITRON EMISSION TOMOGRAPHY [J].
BERGSTROM, M ;
BOETHIUS, J ;
ERIKSSON, L ;
GREITZ, T ;
RIBBE, T ;
WIDEN, L .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (01) :136-141
[2]  
BERRIDGE MS, 1990, J NUCL MED, V31, P1727
[3]  
BOHM C, 1983, AM J NEURORADIOL, V4, P731
[4]   A COMPUTERIZED ADJUSTABLE BRAIN ATLAS [J].
BOHM, C ;
GREITZ, T ;
ERIKSSON, L .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (11) :687-689
[5]  
Bohm C, 1986, Acta Radiol Suppl, V369, P449
[6]  
CHERRY S, 1992, IEEE T NUCL SCI, V2, P960
[7]   3D PET USING A CONVENTIONAL MULTISLICE TOMOGRAPH WITHOUT SEPTA [J].
CHERRY, SR ;
DAHLBOM, M ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :655-668
[8]   EVALUATION OF A 3D RECONSTRUCTION ALGORITHM FOR MULTISLICE PET SCANNERS [J].
CHERRY, SR ;
DAHLBOM, M ;
HOFFMAN, EJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03) :779-790
[9]   IMPROVED DETECTION OF FOCAL CEREBRAL BLOOD-FLOW CHANGES USING 3-DIMENSIONAL POSITRON EMISSION TOMOGRAPHY [J].
CHERRY, SR ;
WOODS, RP ;
HOFFMAN, EJ ;
MAZZIOTTA, JC .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1993, 13 (04) :630-638
[10]  
Damasio AR, 1992, SCI AM, V267, P63