ION INCLUSION INTO LANGMUIR-BLODGETT-FILMS STUDIED ON A QUARTZ - CRYSTAL MICROBALANCE

被引:8
作者
ROSER, SJ
LOVELL, MR
机构
来源
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS | 1995年 / 91卷 / 12期
关键词
D O I
10.1039/ft9959101783
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The potential of a simple quartz crystal microbalance (QCM) system for the study of ion inclusion into Langmuir-Blodgett (LB) films is demonstrated for cadmium docosanoate multilayers over a range of pH values which cover the range of unbound acid films to the high pH salt films. The reproducibility of the deposition process, the number of ions bound per fatty acid molecule and the inclusion of water into the film are measured as a function of pH and compared with values from X-ray reflection measurements. The microscopic drying process and its relevance to film reproducibility are also investigated. There is a slight, significant change in the areal density of the fatty acid component as acid films are converted to fully bound ionic soap films, in addition to the well documented change in the unit-cell c-axis.
引用
收藏
页码:1783 / 1786
页数:4
相关论文
共 13 条
[1]   DYNAMIC CONTACT ANGLES AND DEPOSITION EFFICIENCY FOR TRANSFER OF DOCOSANOIC ACID ON TO MICA FROM CDCL2 SUBPHASES AS A FUNCTION OF PH [J].
AVEYARD, R ;
BINKS, BP ;
FLETCHER, PDI ;
YE, X .
THIN SOLID FILMS, 1992, 210 (1-2) :36-38
[2]   EXPERIMENTAL ASPECTS OF USE OF THE QUARTZ CRYSTAL MICROBALANCE IN SOLUTION [J].
BRUCKENSTEIN, S ;
SHAY, M .
ELECTROCHIMICA ACTA, 1985, 30 (10) :1295-1300
[3]   STRUCTURE AND TEMPERATURE-DEPENDENCE OF FATTY-ACID LANGMUIR-BLODGETT FILMS STUDIED BY NEUTRON AND X-RAY-SCATTERING [J].
BUHAENKO, MR ;
GRUNDY, MJ ;
RICHARDSON, RM ;
ROSER, SJ .
THIN SOLID FILMS, 1988, 159 :253-265
[4]   DYNAMIC FILM RIGIDITY OBSERVATIONS DURING ELECTROCHEMICAL DEPOSITION OF POLYBITHIOPHENE FILMS [J].
GLIDLE, A ;
HILLMAN, AR ;
BRUCKENSTEIN, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 318 (1-2) :411-420
[5]  
HAVINGA E, 1952, RECL TRAV CHIM PAY B, V71, P72
[6]   QUARTZ CRYSTAL MICROBALANCE THIN-FILM DISSOLUTION RATE MONITOR [J].
HINSBERG, WD ;
KANAZAWA, KK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (03) :489-492
[7]  
LEIVELLER F, 1994, LANGMUIR, V10, P819
[8]   NOVEL APPLICATION OF THE QUARTZ CRYSTAL MICROBALANCE TO STUDY LANGMUIR-BLODGETT-FILMS [J].
MCCAFFREY, RR ;
BRUCKENSTEIN, S ;
PRASAD, PN .
LANGMUIR, 1986, 2 (02) :228-229
[9]  
MUSGROVE R, 1991, THESIS U BRISTOL
[10]   PIEZOELECTRIC CRYSTAL BIOSENSORS [J].
NGEHNGWAINBI, J ;
SULEIMAN, AA ;
GUILBAULT, GG .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (01) :13-26