HIGH-RESOLUTION RENAL DIFFUSION IMAGING USING A MODIFIED STEADY-STATE FREE PRECESSION SEQUENCE

被引:13
作者
DING, SJ
TRILLAUD, H
YONGBI, M
ROLETT, EL
WEAVER, JB
DUNN, JF
机构
[1] DARTMOUTH HITCHCOCK MED CTR,DEPT DIAGNOST RADIOL,NMR RES CTR,HANOVER,NH
[2] HOP PELLEGRIN,SERV RADIOL,F-33076 BORDEAUX,FRANCE
关键词
SSFP; DIFFUSION; RENAL IMAGING; MOTION REDUCTION;
D O I
10.1002/mrm.1910340415
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A modified steady-state free precession (SSFP) diffusion sequence is proposed for high resolution renal imaging, A pair of bipolar diffusion gradients was used to minimize the errors in measured apparent diffusion coefficient (ADC) caused by variations in T-1, T-2, and RF flip angle that have been observed with previously employed SSFP diffusion sequences, Motion sensitivity was reduced by the use of compensated gradients, frame-by-frame averaging, and a repetition time of 22 ms, which for a single-acquisition 128 x 128 image requires only 3 s. High resolution was achieved by signal averaging, The modified sequence was applied to in vivo diffusion measurements. In six normal rat kidneys the ADCs (mean+/-SD; x 10(-3) mm(2)/s) of the cortex, outer medulla, and inner medulla were 2.28 +/- 0.05, 2.38 +/- 0.10, and 2.95 +/- 0.05, respectively, The technique requires relatively large gradients to achieve adequate diffusion weighting.
引用
收藏
页码:586 / 595
页数:10
相关论文
共 36 条
[1]   MECHANISM OF DETECTION OF ACUTE CEREBRAL-ISCHEMIA IN RATS BY DIFFUSION-WEIGHTED MAGNETIC-RESONANCE MICROSCOPY [J].
BENVENISTE, H ;
HEDLUND, LW ;
JOHNSON, GA .
STROKE, 1992, 23 (05) :746-754
[2]   DIFFUSION-WEIGHTED IMAGING STUDIES OF CEREBRAL-ISCHEMIA IN GERBILS - POTENTIAL RELEVANCE TO ENERGY FAILURE [J].
BUSZA, AL ;
ALLEN, KL ;
KING, MD ;
VANBRUGGEN, N ;
WILLIAMS, SR ;
GADIAN, DG .
STROKE, 1992, 23 (11) :1602-1612
[3]   THE DIFFUSION SENSITIVITY OF FAST STEADY-STATE FREE PRECESSION IMAGING [J].
BUXTON, RB .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) :235-243
[4]   HETEROGENEITY OF INTRACORTICAL PERITUBULAR PLASMA-FLOW IN RAT-KIDNEY [J].
COELHO, JB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 233 (04) :F333-F341
[5]  
COLLINS DJ, 1992, 11 ANN M SOC MAGN RE, P3826
[6]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[7]   PHASE AND INTENSITY ANOMALIES IN FOURIER TRANSFORM NMR [J].
FREEMAN, R ;
HILL, HDW .
JOURNAL OF MAGNETIC RESONANCE, 1971, 4 (03) :366-&
[8]   CALIBRATION IN ACCURATE SPIN-ECHO SELF-DIFFUSION MEASUREMENTS USING H-1 AND LESS-COMMON NUCLEI [J].
HOLZ, M ;
WEINGARTNER, H .
JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (01) :115-125
[9]   MATRIX TREATMENT OF NUCLEAR INDUCTION [J].
JAYNES, ET .
PHYSICAL REVIEW, 1955, 98 (04) :1099-1105
[10]  
JOHNSON GA, 1993, MAGN RESON QUART, V9, P1