EXCITATION MODES FOR FOURIER TRANSFORM-ION CYCLOTRON-RESONANCE MASS-SPECTROMETRY

被引:100
作者
SCHWEIKHARD, L
MARSHALL, AG
机构
[1] OHIO STATE UNIV,DEPT CHEM & BIOCHEM,120 W 18TH AVE,COLUMBUS,OH 43210
[2] UNIV MAINZ,INST PHYS,W-6500 MAINZ,GERMANY
基金
美国国家科学基金会;
关键词
D O I
10.1016/1044-0305(93)80001-F
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Various geometric configurations for the excitation of coherent ion motion in Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR/MS) are analyzed (in some cases for the first time) with unified notation. The instantaneous power absorption, F . v, in which v is ion velocity and F the force produced by the applied excitation electric field (harmonic, single frequency, on-resonance, in-phase), is time averaged and then set equal to the time rate of change of ion total (cyclotron + magnetron + trapping) energy, to yield a differential equation that is readily solved for the (time-dependent) amplitude of each of the various ion motions. The standard FT-ICR excitation (namely, radial dipolar) is reviewed. The effects of quadrature and radial quadrupolar excitation on ion radial (cyclotron and magnetron) motions are also reviewed. Frictional damping is shown to decrease the ion cyclotron orbital radius and trapping amplitude but increase the magnetron radius. Feedback excitation (i.e., excitation at the simultaneously detected ion cyclotron orbital frequency of the same ion packet) is introduced and analyzed as a means for exciting ions whose cyclotron frequency changes during excitation (as for relativistically shifted low-mass ions). In contrast to conventional radial dipolar excitation, axial dipolar excitation of the trapping motion leads to a mass-dependent ion motional amplitude. Parametric (i.e., axial quadrupolar) excitation is shown to produce an exponential increase in the ion motional amplitudes (hyperbolic sine and hyperbolic cosine amplitude for cyclotron and magnetron radii, respectively). More detailed consideration of parametric excitation leads to an optimal ion initial radial position in parametric-mode Fr-ICR/MS.
引用
收藏
页码:433 / 452
页数:20
相关论文
共 78 条
[1]   EJECTION OF LOW-MASS CHARGED-PARTICLES IN HIGH MAGNETIC-FIELD ICR SPECTROMETERS [J].
ALLEMANN, M ;
KOFEL, P ;
KELLERHALS, H ;
WANCZEK, KP .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 75 (01) :47-54
[2]   AN ION EJECTION TECHNIQUE FOR STUDY OF ION-MOLECULE REACTIONS WITH ION CYCLOTRON RESONANCE SPECTROSCOPY [J].
BEAUCHAMP, JL ;
ARMSTRONG, JT .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (01) :123-+
[3]   MASS MEASUREMENTS OF VERY HIGH-ACCURACY BY TIME-OF-FLIGHT ION-CYCLOTRON RESONANCE OF IONS INJECTED INTO A PENNING TRAP [J].
BECKER, S ;
BOLLEN, G ;
KERN, F ;
KLUGE, HJ ;
MOORE, RB ;
SAVARD, G ;
SCHWEIKHARD, L ;
STOLZENBERG, H .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 99 (1-2) :53-77
[4]   RADIAL ION-TRANSPORT DUE TO RESISTIVE-WALL DESTABILIZATION IN FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 108 (2-3) :255-268
[5]   OPEN TRAPPED ION CELL GEOMETRIES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3) :215-230
[6]   ELIMINATION OF AXIAL EJECTION DURING EXCITATION WITH A CAPACITIVELY COUPLED OPEN TRAPPED-ION CELL FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :177-180
[7]   THE ACCURACY OF HEAVY-ION MASS MEASUREMENTS USING TIME OF FLIGHT-ION CYCLOTRON-RESONANCE IN A PENNING TRAP [J].
BOLLEN, G ;
MOORE, RB ;
SAVARD, G ;
STOLZENBERG, H .
JOURNAL OF APPLIED PHYSICS, 1990, 68 (09) :4355-4374
[8]   PRECISION SPECTROSCOPY OF A CHARGED-PARTICLE IN AN IMPERFECT PENNING TRAP [J].
BROWN, LS ;
GABRIELSE, G .
PHYSICAL REVIEW A, 1982, 25 (04) :2423-2425
[9]   GEONIUM THEORY - PHYSICS OF A SINGLE ELECTRON OR ION IN A PENNING TRAP [J].
BROWN, LS ;
GABRIELSE, G .
REVIEWS OF MODERN PHYSICS, 1986, 58 (01) :233-311
[10]   THE INFINITY CELL - A NEW TRAPPED-ION CELL WITH RADIOFREQUENCY COVERED TRAPPING ELECTRODES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CARAVATTI, P ;
ALLEMANN, M .
ORGANIC MASS SPECTROMETRY, 1991, 26 (05) :514-518