MEASUREMENT OF BRAIN ACTIVITY WITH BOLUS ADMINISTRATION OF CONTRAST AGENT AND GRADIENT-ECHO MR IMAGING

被引:31
作者
ZIGUN, JR
FRANK, JA
BARRIOS, FA
JONES, DW
FOO, TKF
MOONEN, CTW
PRESS, DZ
WEINBERGER, DR
机构
[1] NIMH,NEUROSCI CTR ST ELIZABETHS,INTRAMURAL RES PROGRAM,WASHINGTON,DC 20032
[2] GE MED SYST,MILWAUKEE,WI
[3] NIH,DIAGNOST RADIOL RES PROGRAM,BETHESDA,MD 20892
[4] NIH,IN VIVO NMR RES CTR,BIOMED ENGN INSTRUMENTAT PROGRAM,BETHESDA,MD 20892
[5] NIH,DEPT DIAGNOST RADIOL,BETHESDA,MD 20892
关键词
BLOOD; VOLUME; BRAIN; FUNCTION; MR; WHITE MATTER; MAGNETIC RESONANCE (MR); RAPID IMAGING;
D O I
10.1148/radiology.186.2.8421733
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was performed to measure changes in cerebral blood volume (CBV) associated with visual activation by use of bolus administration of contrast agent and conventional, clinically configured magnetic resonance (MR) hardware and software. Fast gradient-recalled acquisition in the steady state technique was used to study five healthy subjects during visual activation and a control dark state. MR images were obtained every 2.048 seconds for 2 minutes. A bolus of gadopentetate dimeglumine was injected during visual stimulation and darkness. Cine images produced from the series of rapid images clearly depicted arterial, capillary, and venous phases. Analysis of serial concentration maps derived from the rapid images revealed expected differences between the relative CBV of gray matter and that of white matter, as well as significantly increased relative CBV in calcarine cortex during visual activation versus the control state (mean increase, 15.24%; range, 6.41%-27.78%; P < .05). These results confirm those reported in echo-planar imaging studies and demonstrate that brain function can be assessed with the bolus method by means of MR imaging hardware and software with conventional clinical configurations.
引用
收藏
页码:353 / 356
页数:4
相关论文
共 14 条
[1]   FUNCTIONAL CEREBRAL IMAGING BY SUSCEPTIBILITY-CONTRAST NMR [J].
BELLIVEAU, JW ;
ROSEN, BR ;
KANTOR, HL ;
RZEDZIAN, RR ;
KENNEDY, DN ;
MCKINSTRY, RC ;
VEVEA, JM ;
COHEN, MS ;
PYKETT, IL ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) :538-546
[2]   FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING [J].
BELLIVEAU, JW ;
KENNEDY, DN ;
MCKINSTRY, RC ;
BUCHBINDER, BR ;
WEISSKOFF, RM ;
COHEN, MS ;
VEVEA, JM ;
BRADY, TJ ;
ROSEN, BR .
SCIENCE, 1991, 254 (5032) :716-719
[3]  
EDELMAN RR, 1990, RADIOLOGY, V176, P21
[4]   MR FLUOROSCOPY - INITIAL CLINICAL-STUDIES [J].
FARZANEH, F ;
RIEDERER, SJ ;
LEE, JN ;
TASCIYAN, T ;
WRIGHT, RC ;
SPRITZER, CE .
RADIOLOGY, 1989, 171 (02) :545-549
[5]  
FOO TKF, 1990, SOC MAGNETIC RESONAN, P1308
[6]   STIMULUS RATE DEPENDENCE OF REGIONAL CEREBRAL BLOOD-FLOW IN HUMAN STRIATE CORTEX, DEMONSTRATED BY POSITRON EMISSION TOMOGRAPHY [J].
FOX, PT ;
RAICHLE, ME .
JOURNAL OF NEUROPHYSIOLOGY, 1984, 51 (05) :1109-1120
[7]   MEASUREMENT OF TISSUE BLOOD-FLOW USING INTRAVASCULAR RELAXATION AGENTS AND MAGNETIC-RESONANCE-IMAGING [J].
GORE, JC ;
MAJUMDAR, S .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :242-248
[8]   FAST MR-IMAGING - TECHNIQUES AND CLINICAL-APPLICATIONS [J].
HAACKE, EM ;
TKACH, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :951-964
[9]   QUANTITATIVE MEASUREMENT OF LOCAL CEREBRAL BLOOD-FLOW IN HUMANS BY POSITRON COMPUTED-TOMOGRAPHY AND O-15-WATER [J].
HUANG, SC ;
CARSON, RE ;
HOFFMAN, EJ ;
CARSON, J ;
MACDONALD, N ;
BARRIO, JR ;
PHELPS, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1983, 3 (02) :141-153
[10]  
KEGELES LS, IN PRESS AM J PHSYL