VARIABILITY IN THE MEASUREMENT OF NEBULIZED AEROSOL DEPOSITION IN MAN

被引:45
作者
THOMAS, SHL
ODOHERTY, MJ
PAGE, CJ
NUNAN, TO
机构
[1] UNITED MED & DENT SCH GUYS & ST THOMAS HOSP,DIV PHARMACOL SCI & TOXICOL,LONDON,ENGLAND
[2] ST THOMAS HOSP,DEPT NUCL MED,LONDON SE1 7EH,ENGLAND
关键词
AEROSOLS; NEBULIZERS; PULMONARY DEPOSITION; REPEATABILITY; VARIABILITY;
D O I
10.1042/cs0810767
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
1. This study was performed to determine the variability of two different scintigraphic methods of measuring pulmonary aerosol deposition, and to examine nebulizer particle size and drug output as potential sources of this variability. 2. A radioaerosol was produced from a 3 ml solution of 99mTc-labelled colloidal human serum albumin (0.05 mg, 37 MBq) using a standard jet nebulizer and air compressor. This was inhaled on three separate occasions by nine healthy male subjects. On one of these occasions, a further inhalation was performed to assess immediate repeatability using increased 99mTc activity (92 MBq). 3. Intrapulmonary aerosol deposition was measured with a gamma-camera and was corrected for tissue attenuation and geometric distribution by using two different methods. 4. Estimated mean pulmonary deposition was 4.3% of the nebulizer dose using a lung phantom correction method, and 6.1% using a tissue attenuation method. For these two methods respectively variability between subjects (coefficient of variation) was 54 and 47%. For both methods, within-subject variability (coefficient of variation) was 37% between occasions and 23% within occasions. 5. The particle-size output of several nebulizers was highly reproducible (coefficient of variation < 4%), but the nebulizer mass and radionuclide output of two nebulizers was more variable (coefficient of variation 5-19%), and appeared to be an important contributor to the variability in pulmonary aerosol deposition. 6. The data presented here for pulmonary deposition, used with appropriate power statistics formulae, can be used to estimate the sample sizes required for comparative studies of lung aerosol deposition.
引用
收藏
页码:767 / 775
页数:9
相关论文
共 33 条
[11]   TECHNIQUE FOR THE ABSOLUTE MEASUREMENT OF ACTIVITY USING A GAMMA-CAMERA AND COMPUTER [J].
FLEMING, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (01) :176-180
[12]  
FORGE NI, 1991, NUCL MED COMMUN, V12, P296
[13]  
HODSON ME, 1981, LANCET, V2, P1137
[14]   QUANTITATIVE DEPOSITION OF AEROSOLIZED GENTAMICIN IN CYSTIC-FIBROSIS [J].
ILOWITE, JS ;
GORVOY, JD ;
SMALDONE, GC .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (06) :1445-1449
[15]   A PILOT-STUDY OF AEROSOLIZED AMILORIDE FOR THE TREATMENT OF LUNG-DISEASE IN CYSTIC-FIBROSIS [J].
KNOWLES, MR ;
CHURCH, NL ;
WALTNER, WE ;
YANKASKAS, JR ;
GILLIGAN, P ;
KING, M ;
EDWARDS, LJ ;
HELMS, RW ;
BOUCHER, RC .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 322 (17) :1189-1194
[16]  
MACEY DJ, 1982, J NUCL MED, V23, P731
[17]   RIBAVIRIN AEROSOL TREATMENT OF INFLUENZA-B VIRUS-INFECTION [J].
MCCLUNG, HW ;
KNIGHT, V ;
GILBERT, BE ;
WILSON, SZ ;
QUARLES, JM ;
DIVINE, GW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1983, 249 (19) :2671-2674
[18]   DEPOSITION OF CARBENICILLIN AEROSOLS IN CYSTIC-FIBROSIS - EFFECTS OF NEBULIZER SYSTEM AND BREATHING PATTERN [J].
NEWMAN, SP ;
WOODMAN, G ;
CLARKE, SW .
THORAX, 1988, 43 (04) :318-322
[19]  
NEWMAN SP, 1986, EUR J RESPIR DIS, V69, P160
[20]   EVALUATION OF JET NEBULIZERS FOR USE WITH GENTAMICIN SOLUTION [J].
NEWMAN, SP ;
PELLOW, PGD ;
CLAY, MM ;
CLARKE, SW .
THORAX, 1985, 40 (09) :671-676