COMPARISON OF BROAD-BAND ULTRASOUND ATTENUATION TO SINGLE X-RAY ABSORPTIOMETRY MEASUREMENTS AT THE CALCANEUS IN POSTMENOPAUSAL WOMEN

被引:61
作者
SALAMONE, LM [1 ]
KRALL, EA [1 ]
HARRIS, S [1 ]
DAWSONHUGHES, B [1 ]
机构
[1] TUFTS UNIV,USDA,HUMAN NUTR RES CTR AGING,CALCIUM & BONE METAB LAB,BOSTON,MA 02111
关键词
CALCANEUS; ULTRASOUND; BONE MINERAL DENSITY; PRECISION;
D O I
10.1007/BF00296056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Broadband ultrasound attenuation (BUA), a radiation-free and portable technology, may be useful in assessing bone density and fracture risk. In this study, we compared cross-sectional BUA measurements to the more established single energy X-ray absorptiometry measurements of bone mineral density (BMD) at the calcaneus in 259 healthy postmenopausal women, aged 45-76 years. Paired measurements with repositioning of the subject's dominant heel were made consecutively by each method. A coefficient of variation (CV) for each method was calculated for each individual from the paired scans. BUA and BMD of the heel were also compared with BMD of the lumbar spine and femoral neck, as measured by dual energy X-ray absorptiometry. BUA was significantly correlated with BMD at the calcaneus (r = 0.66, P < 0.01). Heel BUA was also correlated with lumbar spine BMD (r = 0.43, P < 0.01) and femoral neck BMD (r = 0.43, P < 0.01) but the correlations were lower than those between heel BMD and spine (r = 0.63, P < 0.01) or femoral neck BMD (r = 0.62, P < 0.01). The mean CV for heel BUA (3.60 +/- 3.50%) was significantly greater than that for heel BMD (1.06 +/- 0.99%, P < 0.01). The moderate correlation of calcaneal BUA and BMD, the lower correlations of BUA than heel BMD with both spine and hip BMD, and lower precision of BUA indicate BUA does not predict bone density as effectively as absorptiometry, the current standard methodology.
引用
收藏
页码:87 / 90
页数:4
相关论文
共 22 条
  • [1] ULTRASOUND ATTENUATION OF THE CALCANEUS - A SENSITIVE AND SPECIFIC DISCRIMINATOR OF OSTEOPENIA IN POSTMENOPAUSAL WOMEN
    AGREN, M
    KARELLAS, A
    LEAHEY, D
    MARKS, S
    BARAN, D
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1991, 48 (04) : 240 - 244
  • [2] Baran D T, 1991, Osteoporos Int, V1, P110, DOI 10.1007/BF01880452
  • [3] ULTRASOUND ATTENUATION OF THE OS CALCIS IN WOMEN WITH OSTEOPOROSIS AND HIP-FRACTURES
    BARAN, DT
    KELLY, AM
    KARELLAS, A
    GIONET, M
    PRICE, M
    LEAHEY, D
    STEUTERMAN, S
    MCSHERRY, B
    ROCHE, J
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1988, 43 (03) : 138 - 142
  • [4] ULTRASOUND ATTENUATION OF THE CALCANEUS IN THE FEMALE-POPULATION - NORMATIVE DATA
    DAMILAKIS, JE
    DRETAKIS, E
    GOURTSOYIANNIS, NC
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (03) : 180 - 183
  • [5] GLUER CC, 1992, J BONE MINER RES, V7, P1071
  • [6] BONE MASS MEASURED BY PHOTON-ABSORPTIOMETRY - COMPARISON OF FOREARM, HEEL, AND SPINE
    HANSEN, MA
    RIIS, BJ
    OVERGAARD, K
    HASSAGER, C
    CHRISTIANSEN, C
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 (05) : 517 - 523
  • [7] MEASUREMENTS OF BROAD-BAND ULTRASONIC-ATTENUATION IN THE CALCANEUS IN PREMENOPAUSAL AND POSTMENOPAUSAL WOMEN
    HERD, RJM
    RAMALINGHAM, T
    RYAN, PJ
    FOGELMAN, I
    BLAKE, GM
    [J]. OSTEOPOROSIS INTERNATIONAL, 1992, 2 (05) : 247 - 251
  • [8] PRECISION AND STABILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENTS
    JOHNSON, J
    DAWSONHUGHES, B
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1991, 49 (03) : 174 - 178
  • [9] KAUFMAN JJ, 1993, J BONE MINER RES, V8, P517
  • [10] LANCASTER EK, 1989, J BONE MINER RES, V4, P507