摘要
With a newly developed magnetic resonance (MR) technique for blood flow measurements, qualitative and quantitative information on both flow volume and flow velocity in the great vessels can be obtained. MR flow quantitation is performed with a gradientecho MR sequence with high temporal resolution enabling measurements at frequent intervals throughout the cardiac cycle. MR flow quantitation uses the phase rather than the amplitude of the MR signal to reconstruct the images. These images, often referred to as MR velocity maps or velocity-encoded cine MR images, are two-dimensional displays of flow velocity. From these velocity maps, velocity and volume flow data can be obtained. Previous validation experiments have demonstrated the accuracy of MR velocity mapping, and this technique is now being applied successfully in several clinical fields. MR velocity mapping may be of considerable value when Doppler echocardiography results are unsatisfactory or equivocal, particularly because MR is suited for the analysis of volumetric flow and complex flow patterns. Among the vastly growing number of clinical cardiovascular applications that have been reported are the great arteries and veins, coronary vessels, valvular disease, and the abdominal and peripheral vessels. These items are reviewed, and some aspects of the technique that need improvement are discussed. © 1993.
引用
收藏
页码:1439 / 1456
页数:18
相关论文
共 122 条
  • [41] INVIVO VALIDATION OF MR VELOCITY IMAGING
    FIRMIN, DN
    NAYLER, GL
    KLIPSTEIN, RH
    UNDERWOOD, SR
    REES, RSO
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) : 751 - 756
  • [42] ECHO-PLANAR HIGH-RESOLUTION FLOW VELOCITY MAPPING
    FIRMIN, DN
    KLIPSTEIN, RH
    HOUNSFIELD, GL
    PALEY, MP
    LONGMORE, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) : 316 - 327
  • [43] GALJEE MA, 1992, 11TH P ANN M SOC MAG, P2508
  • [44] GROEN JP, 1987, 6TH P ANN M SOC MAGN, P868
  • [45] REAL-TIME FLOW MEASUREMENTS USING ECHO-PLANAR IMAGING
    GUILFOYLE, DN
    GIBBS, P
    ORDIDGE, RJ
    MANSFIELD, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) : 1 - 8
  • [46] HIGGINS CB, 1991, CIRCULATION, V84, pI198
  • [47] HOFMAN MBM, 1991, 10TH P SMRM ANN M, P810
  • [48] AORTIC REGURGITATION - QUANTITATION WITH MR IMAGING VELOCITY MAPPING
    HONDA, N
    MACHIDA, K
    HASHIMOTO, M
    MAMIYA, T
    TAKAHASHI, T
    KAMANO, T
    KASHIMADA, A
    INOUE, Y
    TANAKA, S
    YOSHIMOTO, N
    MATSUO, H
    [J]. RADIOLOGY, 1993, 186 (01) : 189 - 194
  • [49] KARWATOWSKI SP, 1992, 11TH P ANN M SOC MAG, P2521
  • [50] KARWATOWSKI SP, 1992, 11TH P ANN M SOC MAG, P2522