DETERMINATION OF FEMTOMOLE CONCENTRATIONS OF CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION

被引:47
作者
HIGASHIDATE, S [1 ]
IMAI, K [1 ]
机构
[1] UNIV TOKYO,BRANCH HOSP PHARM,3-28-6 MEJIRODAI,BUNKYOU KU,TOKYO 112,JAPAN
关键词
PLASMA CATECHOLAMINE; HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY; ETHYLENEDIAMINE CONDENSATION; PEROXYOXALATE CHEMILUMINESCENCE; BIS[4-NITRO-2-(3,6,9-TRIOXADECYLOXYCARBONYL)PHENYL] OXALATE;
D O I
10.1039/an9921701863
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive method for determination of the plasma catecholamines, norepinephrine (NE), epinephrine (E) and dopamine (DA) is described. The method consists of the extraction of the catecholamines, using 3,4-dihydroxybenzylamine as internal standard, from plasma with alumina (5 mg), followed by a reversed-phase column separation, on-column fluorogenic derivatization with ethylenediamine (ED) and post-column peroxyoxalate chemiluminescent reaction detection utilizing bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl] oxalate (TDPO) and hydrogen peroxide. In order to optimize the reaction conditions for high-performance liquid chromatography to obtain highly sensitive detection, the effects of changing reagent compositions on the chemiluminescence yield were investigated. The following are the optimized conditions. Eluent, a mixture of 50 mmol l-1 potassium acetate (pH 3.20)-50 mmol l-1 potassium phosphate (pH 3.20)-acetonitrile (90.15 + 4.85 + 3 v/v/v) containing 1 mmol l-1 sodium hexanesulfonate (40-degrees-C) and flow rate, 0.5 ml min-1. Fluorogenic reagent solution, 105 mmol l-1 ED and 175 mmol l-1 imidazole in acetonitrile-ethanol (90 + 10 v/v) and flow rate, 0.25 ml min-1. Reaction coil (15 m x 0.5 mm i.d.) heated at 80-degrees-C. Chemiluminogenic reagent solution, 0.25 mmol l-1 TDPO, 150 mmol l-1 hydrogen peroxide and 110 mmol l-1 trifluoroacetic acid in dioxane-ethyl acetate (50:50 v/v) and flow rate, 1.4 ml min-1. The detection limits for all the catecholamines were 1 fmol (signal-to-noise ratio at 2). The standard deviations of the method for the determination of NE, E and DA added to rat plasma (2.5 nM) were 3, 3 and 4%, respectively. The concentrations of rat plasma catecholamines measured by the proposed method were NE 1.21, E 0.12 and DA 0.63 pmol ml-1 and were lower than those obtained previously by radioenzymic-paper chromatography.
引用
收藏
页码:1863 / 1868
页数:6
相关论文
共 29 条
[21]   DETERMINATION OF THE FLUORESCENT DRUGS DIPYRIDAMOLE AND BENZYDAMINE IN RAT PLASMA BY LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION [J].
NISHITANI, A ;
TSUKAMOTO, Y ;
KANDA, S ;
IMAI, K .
ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) :247-253
[22]   MEASUREMENT OF CATECHOLAMINES, THEIR PRECURSOR AND METABOLITES IN HUMAN-URINE AND PLASMA BY SOLID-PHASE EXTRACTION FOLLOWED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DERIVATIZATION [J].
NOHTA, H ;
YAMAGUCHI, E ;
OHKURA, Y ;
WATANABE, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 493 (01) :15-26
[23]   DETERMINATION OF SERUM ESTRADIOL BY NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION [J].
NOZAKI, O ;
OHBA, Y ;
IMAI, K .
ANALYTICA CHIMICA ACTA, 1988, 205 (1-2) :255-260
[24]  
POPPER CW, 1977, J PHARMACOL EXP THER, V202, P144
[25]   MODIFIED ETHYLENEDIAMINE CONDENSATION METHOD AND ITS APPLICATION IN ANALYSIS OF CATECHOLAMINES BY ION-EXCHANGE CHROMATOGRAPHY [J].
SEKI, T .
JOURNAL OF CHROMATOGRAPHY, 1978, 155 (02) :415-420
[26]   DETERMINATION OF A NOVEL POTENT IMMUNOSUPPRESSANT (FK-506) IN RAT SERUM AND LYMPH BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION [J].
TAKADA, K ;
OHHASHI, M ;
YOSHIKAWA, H ;
MURANISHI, S ;
NISHIYAMA, M ;
YOSHIDA, H ;
HATA, T ;
TANAKA, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 530 (01) :212-218
[27]   USE OF 4-(N,N-DIMETHYLAMINOSULPHONYL)-7-FLUORO-2,1,3-BENZOXADIAZOLE AS A LABELING REAGENT FOR PEROXYOXALATE CHEMILUMINESCENCE DETECTION AND ITS APPLICATION TO THE DETERMINATION OF THE BETA-BLOCKER METOPROLOL IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
UZU, S ;
IMAI, K .
ANALYST, 1991, 116 (12) :1353-1357
[28]   GAS-LIQUID-CHROMATOGRAPHIC AND MASS FRAGMENTOGRAPHIC DETERMINATION OF CATECHOLAMINES IN HUMAN PLASMA [J].
WANG, MT ;
IMAI, K ;
YOSHIOKA, M ;
TAMURA, Z .
CLINICA CHIMICA ACTA, 1975, 63 (01) :13-19
[29]  
YAMATODANI A, 1981, CLIN CHEM, V27, P1983