MEASUREMENT OF FORCES DURING LARYNGOSCOPY

被引:52
作者
BUCX, MJL
SCHECK, PAE
VANGEEL, RTM
DENOUDEN, AH
NIESING, R
机构
[1] UNIV HOSP DIJKZIGT,3015 GD ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV,CENT RES WORKSHOPS,3015 GD ROTTERDAM,NETHERLANDS
关键词
EQUIPMENT; LARYNGOSCOPE; INTUBATION; TRACHEAL;
D O I
10.1111/j.1365-2044.1992.tb02180.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The forces transmitted by the laryngoscope blade onto the base of the tongue are assumed to be a major cardiovascular stimulus. This study investigates the various forces applied onto a Macintosh laryngoscope during laryngoscopy. The forces acting along the axis of the handle are described, as well as the forces exerted by the anaesthetist to prevent the laryngoscope from turning. Based on a relatively simple technique, a modified laryngoscope has been designed to measure these forces. Four different laryngoscopic parameters are determined: (1) the duration of laryngoscopy, (2) the maximally applied force, (3) the mean force and (4) the integral of the force over the time (area under the curve). The force measurements of 49 anatomically normal patients undergoing uncomplicated intubation are included in the study. The duration of laryngoscopy was 16.3s (SD 11.8), the applied peak force was 35N (SD 12) and mean force necessary was 20N (SD 6) while the force‐time integral was 324N (SD 194). Copyright © 1992, Wiley Blackwell. All rights reserved
引用
收藏
页码:348 / 351
页数:4
相关论文
共 18 条
[1]   ELECTROCARDIOGRAPHIC STUDIES DURING ENDOTRACHEAL INTUBATION .1. EFFECTS DURING USUAL ROUTINE TECHNICS [J].
BURSTEIN, CL ;
LOPINTO, FJ ;
NEWMAN, W .
ANESTHESIOLOGY, 1950, 11 (02) :224-237
[2]   A MEASURING LARYNGOSCOPE HANDLE - A DEVICE FOR MEASURING THE FORCES APPLIED DURING LARYNGOSCOPY [J].
CHILCOAT, RT ;
ALLEN, FB ;
GERSON, JI ;
GROGONO, AW .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (04) :525-527
[3]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[4]   EFFECT OF TOPICAL LIGNOCAINE ON THE SYMPATHODRENAL RESPONSES TO TRACHEAL INTUBATION [J].
DERBYSHIRE, DR ;
SMITH, G ;
ACHOLA, KJ .
BRITISH JOURNAL OF ANAESTHESIA, 1987, 59 (03) :300-304
[5]   ACUTE HYPERTENSION DURING INDUCTION OF ANAESTHESIA AND ENDOTRACHEAL INTUBATION IN NORMOTENSIVE MAN [J].
FORBES, AM ;
DALLY, FG .
BRITISH JOURNAL OF ANAESTHESIA, 1970, 42 (07) :618-+
[6]  
GOMMERS CM, 1976, MIKRONIEK, V16, P109
[7]   REFLEX CIRCULATORY RESPONSES TO DIRECT LARYNGOSCOPY AND TRACHEAL INTUBATION PERFORMED DURING GENERAL ANESTHESIA [J].
KING, BD ;
HARRIS, LC ;
GREIFENSTEIN, FE ;
ELDER, JD ;
DRIPPS, RD .
ANESTHESIOLOGY, 1951, 12 (05) :556-566
[8]  
Popov E.P., 1976, MECH MATER, VSecond
[9]   MEASURING HANDGRIP FORCE, USING A NEW APPLICATION OF STRAIN-GAUGES [J].
PRONK, CNA ;
NIESING, R .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (01) :127-128
[10]  
ROBERTS JT, 1983, FUNDAMENTALS TRACHEA