EFFECTS OF RESOLUTION, PEAK RATIO AND SAMPLING FREQUENCY IN DIODE-ARRAY FLUORESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY

被引:35
作者
POE, RB [1 ]
RUTAN, SC [1 ]
机构
[1] VIRGINIA COMMONWEALTH UNIV, DEPT CHEM, RICHMOND, VA 23284 USA
关键词
LIQUID CHROMATOGRAPHY; ACCURACY; CHEMOMETRICS; DIODE-ARRAY FLUORESCENCE DETECTION;
D O I
10.1016/0003-2670(93)85298-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, different methods of quantification that use both fluorescence spectral and retention time data were evaluated for accuracy and precision in diode-array fluorescence detection in liquid chromatography. The methods evaluated include the peak height and peak area methods of quantification, an adaptive Kalman filter and the generalized rank annihilation method. All of these methods were used to estimate the concentration of a model led component in the presence of other partially resolved unmodelled components. The peak area and peak height methods of quantification gave the largest errors as the chromatographic resolution was decreased. The generalized rank annihilation method gave the most reliable results when the chromatographic resolution was greater than 0.3. However, this method was affected by retention time shifts between the calibration and unknown samples and the rate at which the spectra were acquired.
引用
收藏
页码:845 / 853
页数:9
相关论文
共 18 条
[1]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[2]   MULTICOMPONENT CALIBRATION AND ANALYSIS IN LIQUID-CHROMATOGRAPHY [J].
CECIL, TL ;
POE, RB ;
RUTAN, SC .
ANALYTICA CHIMICA ACTA, 1991, 250 (01) :37-44
[3]   FLUORESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY WITH AN INTENSIFIED DIODE-ARRAY DETECTOR [J].
CECIL, TL ;
RUTAN, SC .
JOURNAL OF CHROMATOGRAPHY, 1991, 556 (1-2) :495-503
[4]   REALISTIC SIMULATIONS OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ULTRAVIOLET DATA FOR THE EVALUATION OF MULTIVARIATE TECHNIQUES [J].
GERRITSEN, MJP ;
FABER, NM ;
VANRIJN, M ;
VANDEGINSTE, BGM ;
KATEMAN, G .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1992, 12 (03) :257-268
[5]   ACCURACY, PRECISION AND INFORMATION OF THE ADAPTIVE KALMAN FILTER IN CHROMATOGRAPHY [J].
HAYASHI, Y ;
RUTAN, SC .
ANALYTICA CHIMICA ACTA, 1993, 271 (01) :91-100
[6]   EVOLVING FACTOR-ANALYSIS IN THE PRESENCE OF HETEROSCEDASTIC NOISE [J].
KELLER, HR ;
MASSART, DL ;
LIANG, YZ ;
KVALHEIM, OM .
ANALYTICA CHIMICA ACTA, 1992, 263 (1-2) :29-36
[7]   ARTIFACTS IN EVOLVING FACTOR ANALYSIS-BASED METHODS FOR PEAK PURITY CONTROL IN LIQUID-CHROMATOGRAPHY WITH DIODE-ARRAY DETECTION [J].
KELLER, HR ;
MASSART, DL .
ANALYTICA CHIMICA ACTA, 1992, 263 (1-2) :21-28
[8]   GENERALIZED RANK ANNIHILATION METHOD USING SIMILARITY TRANSFORMATIONS [J].
LI, SS ;
HAMILTON, JC ;
GEMPERLINE, PJ .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :599-607
[9]  
Malinowski E. R., 1988, J CHEMOMETR, V3, P49
[10]   THEORY OF ERROR IN FACTOR-ANALYSIS [J].
MALINOWSKI, ER .
ANALYTICAL CHEMISTRY, 1977, 49 (04) :606-612