COUPLED-COLUMN LIQUID-CHROMATOGRAPHIC ANALYSIS OF EPIRUBICIN AND METABOLITES IN BIOLOGICAL-MATERIAL AND ITS APPLICATION TO OPTIMIZATION OF LIVER-CANCER THERAPY

被引:46
作者
RUDOLPHI, A
VIELHAUER, S
BOOS, KS
SEIDEL, D
BATHGE, IM
BERGER, H
机构
[1] UNIV MUNICH,KLINIKUM GROSSHADERN,INST KLIN CHEM,D-81312 MUNICH,GERMANY
[2] UNIV MUNICH,KLINIKUM GROSSHADERN,INST RADIOL DIAGNOST,D-81312 MUNICH,GERMANY
关键词
COUPLED-COLUMN LC; EPIRUBICIN; RESTRICTED ACCESS MATERIALS; ALKYL-DIOL SILICA; PHARMACOKINETICS;
D O I
10.1016/0731-7085(95)01317-E
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A specific, sensitive and fully automated coupled-column LC method for the determination of the anthracycline cytostatic epirubicin and four metabolites in the biological materials human plasma, liver homogenate and liver tumour homogenate has been developed. System-integrated sample processing was achieved using a new restricted access silica precolumn packing. This porous Alkyl-Diol Silica (ADS) was specially designed for the direct and repetitive injection of proteinaceous samples. It consists of a hydrophilic and electroneutral external particle surface (glyceryl-residues) and a hydrophobic reversed-phase internal surface (butyryl-, octanoyl- or octadecyl-residues). These bimodal chromatographic properties allow retention of low molecular analytes by classical RP-chromatography exclusively at the lipophilic pore surface. Macromolecular constituents of the sample matrix (e.g. proteins) are size-excluded by 5 nm pores and quantitatively eliminated in the interstitial void volume. On-line analysis was performed by coupling a C-4-Alkyl-Diol precolumn (20 x 4 mm i.d., particle size 25 mu m) and a LiChrospher RP Select B analytical column (250 x 4 mm i.d., particle size 5 mu m) via an electrically driven six-port valve. Separation of the parent compound and its metabolites was achieved with a mobile phase consisting of water (0.1% triethylamine, v/v, pH 2.0 adjusted with trichloroacetic acid)-acetonitrile (70:30, v/v) at a flow rate of 1 ml min(-1). The analytes were detected using their natural fluorescence (excitation 445 nm, emission 560 nm). The method described is used for the determination of pharmacokinetics of epirubicin and its metabolites in order to evaluate and optimize treatment regimen of liver cancer chemoembolization therapy.
引用
收藏
页码:615 / 623
页数:9
相关论文
共 41 条
  • [1] ANDERSON DJ, 1993, ANAL CHEM, V65, pR434
  • [2] [Anonymous], 1980, ANAL CHEM, V52, P2242
  • [3] ARCAMONE F, 1995, J MED CHEM, V18, P703
  • [4] ANALYSIS OF ANTITUMOR ANTIBIOTICS BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY (HPLC)
    ASZALOS, A
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 : 69 - 125
  • [5] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC BIOANALYSIS OF ANTHRACYCLINE CYTOSTATIC DRUGS
    BEIJNEN, JH
    UNDERBERG, WJM
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1988, 6 (6-8) : 677 - 685
  • [6] COUPLED-COLUMN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF 1-HYDROXYPYRENE IN URINE OF SUBJECTS EXPOSED TO POLYCYCLIC AROMATIC-HYDROCARBONS
    BOOS, KS
    LINTELMANN, J
    KETTRUP, A
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 600 (02): : 189 - 194
  • [7] ONLINE SAMPLE PROCESSING AND ANALYSIS OF DIOL COMPOUNDS IN BIOLOGICAL-FLUIDS
    BOOS, KS
    WILMERS, B
    SCHLIMME, E
    SAUERBREY, R
    [J]. JOURNAL OF CHROMATOGRAPHY, 1988, 456 (01): : 93 - 104
  • [8] DEVELOPMENT AND PERFORMANCE OF AN AUTOMATED HPLC-ANALYZER FOR CATECHOLAMINES
    BOOS, KS
    WILMERS, B
    SAUERBREY, R
    SCHLIMME, E
    [J]. CHROMATOGRAPHIA, 1987, 24 : 363 - 370
  • [9] BOOS KS, 1991, Patent No. 4130475
  • [10] BOOS KS, 1995, IN PRESS FRESENIUS J