CORONARY-ARTERIES - 3-DIMENSIONAL MR-IMAGING WITH FAT SATURATION AND MAGNETIZATION TRANSFER CONTRAST

被引:171
作者
LI, D
PASCHAL, CB
HAACKE, EM
ADLER, LP
机构
[1] CASE WESTERN RESERVE UNIV,DEPT BIOMED ENGN,CLEVELAND,OH 44106
[2] CASE WESTERN RESERVE UNIV,DEPT PHYS,CLEVELAND,OH 44106
关键词
CORONARY VESSELS; MR; MAGNETIC RESONANCE (MR); VASCULAR STUDIES;
D O I
10.1148/radiology.187.2.8475281
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging of the coronary arteries is a particularly difficult task because of the small size of the vessels and the motion of the heart during the cardiac and respiratory cycles. The authors developed a non-breath-hold three-dimensional (3D) technique to accomplish this goal. Imaging was performed with voxel sizes of 1.50-4.50 mm3. This allows for excellent multiplanar reconstruction to view the coronary arteries from any angle. The short echo time usually makes blood isointense with surrounding tissue since inflow enhancement is weak with a thick-slab 3D method. This problem is overcome by applying fat saturation and magnetization transfer contrast techniques to suppress the signals of fat and myocardium surrounding the coronary arteries. Respiratory motion artifacts are reduced by taking four acquisitions and averaging the data. The authors acquired the first 3-10 cm of both the left and right coronary arteries in most cases in 7-10 minutes with single slab coverage. Acquisition of multiple slabs should further increase the length of coverage of the coronary arteries. Further improvements will occur when respiratory gating is used.
引用
收藏
页码:401 / 406
页数:6
相关论文
共 26 条
[11]   PSEUDO-GATING - ELIMINATION OF PERIODIC MOTION ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING WITHOUT GATING [J].
HAACKE, EM ;
LENZ, GW ;
NELSON, AD .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (02) :162-174
[12]   THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING [J].
HOLSINGER, AE ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) :481-488
[13]   RETROSPECTIVE CARDIAC GATING - A REVIEW OF TECHNICAL ASPECTS AND FUTURE-DIRECTIONS [J].
LENZ, GW ;
HAACKE, EM ;
WHITE, RD .
MAGNETIC RESONANCE IMAGING, 1989, 7 (05) :445-455
[14]   INTRACRANIAL MR ANGIOGRAPHY - APPLICATION OF MAGNETIZATION TRANSFER CONTRAST AND FAT SATURATION TO SHORT GRADIENT-ECHO, VELOCITY-COMPENSATED SEQUENCES [J].
LIN, W ;
TKACH, JA ;
HAACKE, EM ;
MASARYK, TJ .
RADIOLOGY, 1993, 186 (03) :753-761
[15]  
MEYER C, 1992, SOC MAGNETIC RESONAN, P211
[16]   3-DIMENSIONAL MAGNETIZATION-PREPARED RAPID GRADIENT-ECHO IMAGING (3DMP-RAGE) [J].
MUGLER, JP ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (01) :152-157
[17]  
MUGLER JP, 1992, SOC MAGNETIC RESONAN, P431
[18]   MAGNETIC-RESONANCE CORONARY-ARTERY IMAGING [J].
PASCHAL, CB ;
HAACKE, EM ;
ADLER, LP ;
FINELLI, DA .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1992, 15 (01) :23-31
[19]  
PASCHAL CB, 1991, SOC MAGNETIC RESONAN, P1120
[20]  
PASCHAL CG, 1992, 10TH ANN M SOC MAGN