MAGNETIC-RESONANCE IMAGING-GUIDED PREOPERATIVE BREAST LOCALIZATION USING FREEHAND TECHNIQUE

被引:31
作者
BRENNER, RJ
SHELLOCK, FG
ROTHMAN, BJ
GIULIANO, A
机构
[1] ST JOHNS HOSP,SANTA MONICA,CA
[2] TOWER IMAGING,LOS ANGELES,CA 90048
[3] FUTURE DIAGNOST INC,LOS ANGELES,CA
[4] UNIV CALIF LOS ANGELES,SCH MED,LOS ANGELES,CA
关键词
D O I
10.1259/0007-1285-68-814-1095
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A 1.5 cm focus in the breast with intense gadolinium uptake was incidentally detected during magnetic resonance (MR) imaging evaluation of a cluster of microcalcifications. Because the apparent mass was both mammographically and sonographically occult, MR imaging was used to guide a needle by ''freehand technique'' to the lesion, permitting successful pre-operative localization and subsequent surgical excision of the area.
引用
收藏
页码:1095 / 1098
页数:4
相关论文
共 7 条
  • [1] Brenner R J, 1994, Magn Reson Imaging Clin N Am, V2, P705
  • [2] BREAST MASSES - US-GUIDED FINE-NEEDLE ASPIRATION BIOPSY
    FORNAGE, BD
    FAROUX, MJ
    SIMATOS, A
    [J]. RADIOLOGY, 1987, 162 (02) : 409 - 414
  • [3] MR-IMAGING OF THE BREAST - TECHNICAL APPROACH AND CLINICAL-EXPERIENCE
    HARMS, SE
    FLAMIG, DP
    [J]. RADIOGRAPHICS, 1993, 13 (04) : 905 - 912
  • [4] HEYWANGKOBRUNNE.SH, 1993, RADIOLOGY P, V189, P138
  • [5] KAISER W, 1989, RADIOLOGY, V178, P861
  • [6] SPRING HOOKWIRE BREAST LESION LOCALIZER - USE WITH RIGID-COMPRESSION MAMMOGRAPHIC SYSTEMS
    KOPANS, DB
    LINDFORS, K
    MCCARTHY, KA
    MEYER, JE
    [J]. RADIOLOGY, 1985, 157 (02) : 537 - 538
  • [7] MR IMAGING OF SILICONE BREAST IMPLANTS - COMPARISON OF DIFFERENT COIL ARRAYS
    SINHA, S
    GORCZYCA, DP
    DEBRUHL, ND
    SHELLOCK, FG
    GAUSCHE, VR
    BASSETT, LW
    [J]. RADIOLOGY, 1993, 187 (01) : 284 - 286