Extrafocal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams

被引:77
作者
Sharpe, MB [1 ]
Jaffray, DA [1 ]
Battista, JJ [1 ]
Munro, P [1 ]
机构
[1] LONDON REG CANC CTR,ONTARIO CANC TREATMENT & RES FDN,LONDON,ON N6A 4L6,CANADA
关键词
radiation therapy; dose calculation; x-ray beam; head scatter; output factor; beam penumbra; extrafocal radiation;
D O I
10.1118/1.597648
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An extrafocal source model has been developed to explain the dependence of head scatter and beam penumbra on field size. In this model, the x-ray source of a medical linear accelerator is described by two components: a small but intense focal component; and a broadly distributed extrafocal component of low intensity. The extrafocal component is so large that it can be ''eclipsed'' by the field-defining collimators. Extrafocal radiation was found to account for 12% of the energy fluence on the central axis of the 6 MV x-ray beam from a Varian Clinac 2100c accelerator. Head scatter factors were calculated ''in-air'' for symmetric, asymmetric, and half-blocked fields. Calculations agreed with measured values to better than 0.5%, on average. However, head scatter factors for asymmetric fields were underestimated by 1.2% when one of the field dimensions was reduced to 4 cm (the minimum jaw setting that was tested). The extrafocal source model was combined with a convolution/superposition dose calculation algorithm to calculate dose-per-monitor-unit calibration (output) factors and beam dose profiles in water. These dose calculations predict the degradation of the field edge as a function of field size, and calculate output factors to within 0.5%, on average. In the most extreme case of a 4 cm field width, output factors were underestimated by 2%. Dose profiles are predicted without the aid of an empirical fit to measured beam penumbra data. The extrafocal source model will be particularly useful for fields defined by independent jaw and multileaf collimation systems.
引用
收藏
页码:2065 / 2074
页数:10
相关论文
共 40 条
[21]  
Dunscombe P.B., Nieminen J.M., On the field-size dependence of relative output from a linear accelerator, Med. Phys., 19, pp. 1441-1444, (1992)
[22]  
Wilkinson J.M., Rawlinson J.A., Cunningham J.R., An extended source model for the calculation of the primary’ component of a cobalt-60 radiation beam in penumbral regions, AAPM Annual Meeting, Washington, (1970)
[23]  
Cunningham J.R., Shrivastava P.N., Wilkinson J.M., Program IRREG-calculation of dose from irregularly shaped radiation beams, Comput. Prog. Biomed., 2, pp. 192-199, (1972)
[24]  
Sharpe M.B., Battista J.J., Dose calculations using convolution and superposition principles: The orientation of dose spread kernels in divergent x-ray beams, Med. Phys., 20, pp. 1685-1694, (1993)
[25]  
Lutz W.R., Maleki N., Bjarngard B.E., Evaluation of a beam-spot camera for megavoltage x rays, Med. Phys., 15, pp. 614-617, (1988)
[26]  
Loewenthal E., Loewinger E., Bar Avraham E., Bamea G., Measurement of the source size of a 6- and 18-MV radiotherapy linac, Med. Phys., 19, pp. 687-690, (1992)
[27]  
Siddon R.L., Prism representation: a 3D ray-tracing algorithm for radiotherapy applications, Phys. Med. Biol., 30, pp. 817-824, (1985)
[28]  
Boyer A.L., Fourier Convolution Techniques, Proceedings of the Regina Workshop on Convolution, (1986)
[29]  
Kubsad S.S., Mackie T.R., Gehring M.A., Misisco D.J., Paliwal B.R., Mehta M.P., Kinsella T.J., Monte Carlo and convolution dosimetry for stereotactic radiosurgery, Int. J. Radiat. Oncol. Biol. Phys., 19, pp. 1027-1035, (1990)
[30]  
Ahnesjo A., Saxner M., Trepp A., A pencil beam model for photon dose calculation, Med. Phys., 19, pp. 263-273, (1992)