INCIDENCE AND NATURE OF PERITONEAL CATHETER BIOFILM DETERMINED BY ELECTRON AND CONFOCAL LASER-SCANNING MICROSCOPY

被引:34
作者
GORMAN, SP
ADAIR, CG
MAWHINNEY, WM
机构
[1] School of Pharmacy, Medical Biology Centre, The Queen's University of Belfast
关键词
D O I
10.1017/S0950268800051256
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Thirty-two Tenckhoff catheters retrieved from continuous ambulatory peritoneal dialysis patients with a history of peritonitis were examined for microbial biofilm. Confocal laser scanning microscopy was successfully employed to visualize bacteria in biofilm occluded from view by scanning electron microscopy. Occluded but viable microbial biofilm was associated with 17 (81%) catheters from patients free from infection following renal transplant. Mixed isolate biofilm with two or more isolates of coagulase-negative staphylococci or Staphylococcus aureus was found on 41% of these catheters. Clearly visible viable biofilm consisting exclusively of Pseudomonas aeruginosa occurred on all four catheters removed due to recurrent peritonitis. Five (71%) catheters retrieved from patients transferred to haemodialysis had viable biofilm. Antibiotic sensitivities of the biofilm isolates were similar in profile to those reported for non-biofilm isolates from infected dialysate. Persistence of catheter biofilm despite direct contact with therapeutic levels of antibiotics in peritoneal dialysate requires that attention be directed towards improving antibiotic efficacy against peritonitis-causing bacteria in biofilm form.
引用
收藏
页码:551 / 559
页数:9
相关论文
共 21 条
[1]  
DASGUPTA MK, 1987, PERITON DIALYSIS INT, V7, P168
[2]   EFFECT OF VANCOMYCIN HYDROCHLORIDE ON STAPHYLOCOCCUS-EPIDERMIDIS BIOFILM ASSOCIATED WITH SILICONE ELASTOMER [J].
EVANS, RC ;
HOLMES, CJ .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1987, 31 (06) :889-894
[3]   INFLUENCE OF SELECTIVE DECONTAMINATION OF THE DIGESTIVE-TRACT ON MICROBIAL BIOFILM FORMATION ON ENDOTRACHEAL-TUBES FROM ARTIFICIALLY VENTILATED PATIENTS [J].
GORMAN, S ;
ADAIR, C ;
ONEILL, F ;
GOLDSMITH, C ;
WEBB, H .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1993, 12 (01) :9-17
[4]   CONFOCAL LASER-SCANNING MICROSCOPY OF PERITONEAL CATHETER SURFACES [J].
GORMAN, SP ;
MAWHINNEY, WM ;
ADAIR, CG ;
ISSOUCKIS, M .
JOURNAL OF MEDICAL MICROBIOLOGY, 1993, 38 (06) :411-417
[5]  
GORMAN SP, 1991, SOC APPLIED BACTERIO, V27, P271
[6]  
GORMAN SP, 1993, SOC APPL BACTERIOLOG, V30, P95
[7]   APPLICATION OF AN EMPIRICALLY DERIVED GROWTH CURVE MODEL TO CHARACTERIZE STAPHYLOCOCCUS-EPIDERMIDIS BIOFILM DEVELOPMENT ON SILICONE ELASTOMER [J].
HOLMES, CJ ;
EVANS, RC ;
VONESH, E .
BIOMATERIALS, 1989, 10 (09) :625-629
[8]   PREPARATION TECHNIQUES FOR THE ELECTRON-MICROSCOPY OF GRANULAR SLUDGE FROM AN ANAEROBIC DIGESTER [J].
HOWGRAVEGRAHAM, AR ;
WALLIS, FM .
LETTERS IN APPLIED MICROBIOLOGY, 1991, 13 (02) :87-89
[9]  
KLUGE RM, 1983, HEART LUNG, V11, P146
[10]   OPTICAL SECTIONING OF MICROBIAL BIOFILMS [J].
LAWRENCE, JR ;
KORBER, DR ;
HOYLE, BD ;
COSTERTON, JW ;
CALDWELL, DE .