摘要
The rapid-clearing spray chamber design utilizes two critical features for a rapid-clearing system-a nebulizer wash and a high-volume gas flush. The combination of these two features with supporting design features provides a system which can clear out a signal of Fe or Zn from 500 ppm to undetectable levels (below 10 ppb) in about 20 s. A tubular injector is used in the ICP torch to minimize plasma disturbance during the gas flush cycle. Several modifications to the spray chamber were necessary to handle the nebulizer wash efficiently.
引用
收藏
页码:761 / 765
页数:5
相关论文
共 18 条
[1]   THIMBLE GLASS FRIT NEBULIZER FOR ATOMIC SPECTROMETRY [J].
CLIFFORD, RH ;
MONTASER, A ;
SINEX, SA ;
CAPAR, SG .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2777-2784
[2]  
DODD DE, 1983, APPL SPECTROSC, V37, P379
[3]   HEATED SAMPLE INTRODUCTION SYSTEM FOR THE ANALYSIS OF SLURRIES BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
GERVAIS, LS ;
SALIN, ED .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (01) :41-47
[4]   SMALL SPRAY CHAMBER WITH A CONCENTRIC NEBULIZER FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
ISOYAMA, H ;
UCHIDA, T ;
IIDA, C ;
NAKAGAWA, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (04) :307-310
[5]   SMALL SPRAY CHAMBER FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY AND ITS EVALUATION BY A DIGITAL SIGNAL SAMPLING TECHNIQUE [J].
ISOYAMA, H ;
UCHIDA, T ;
NIWA, T ;
IIDA, C ;
NAKAGAWA, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (04) :351-355
[6]   FLOW-INJECTION ANALYSIS WITH INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION-SPECTROSCOPY - CRITICAL COMPARISON OF CONVENTIONAL PNEUMATIC, ULTRASONIC AND DIRECT INJECTION NEBULIZATION [J].
LAFRENIERE, KE ;
RICE, GW ;
FASSEL, VA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1985, 40 (10-12) :1495-1504
[7]  
LEGERE G, 1988, ICP INFORM NEWSL, V13, P521
[8]  
LEGERE G, 1985, ICP INFORM NEWSL, V11, P447
[9]   RAPID THROUGHPUT NEBULIZER SPRAY CHAMBER SYSTEM FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
LUFFER, DR ;
SALIN, ED .
ANALYTICAL CHEMISTRY, 1986, 58 (03) :654-656
[10]   MODIFIED CONCENTRIC GLASS NEBULIZER FOR REDUCTION OF MEMORY EFFECTS IN INDUCTIVELY COUPLED PLASMA SPECTROMETRY [J].
RAMSEY, MH ;
THOMPSON, M ;
COLES, BJ .
ANALYTICAL CHEMISTRY, 1983, 55 (09) :1626-1629