IMMUNOSCINTIGRAPHY WITH ANTIGRANULOCYTE MONOCLONAL-ANTIBODIES FOR THE DIAGNOSIS OF SEPTIC LOOSENING OF HIP PROSTHESES

被引:32
作者
BOUBAKER, A [1 ]
DELALOYE, AB [1 ]
BLANC, CH [1 ]
DUTOIT, M [1 ]
LEYVRAZ, PF [1 ]
DELALOYE, B [1 ]
机构
[1] CHU VAUDOIS,SERV ORTHOPED & CHIRURG APPAREIL MOTEUR,CH-1011 LAUSANNE,SWITZERLAND
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1995年 / 22卷 / 02期
关键词
IMMUNOSCINTIGRAPHY; INFECTION; HIP PROSTHESIS;
D O I
10.1007/BF00838944
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine the value of immunoscintigraphy (IS) with antigranulocyte monoclonal antibodies (Mab) in the diagnosis of subacute or chronic infection of hip prostheses, we prospectively studied 57 patients (23 women and 34 men; age 29-92 years, mean 72.7 years) sent to our institution in the past 6 years for clinical suspicion of septic loosening of a hip prosthesis. Nineteen patients had bilateral prostheses and one of them was studied twice. A total of 78 prostheses were examined. All patients had three-phase bone scans followed by IS with technetium-99m antigranulocyte Mab BW 250/183. Intervals between bone scans and IS varied from 2 days to 4 weeks. Final diagnosis was assessed by culture in 48 cases (articular puncture or intraoperative sampling) and by clinical follow-up of at least 8 months in 30 cases. Twelve prostheses were considered septic and 66 non-septic. The overall sensitivity and specificity were 92% and 64% respectively for bone scans, 67% and 75% for IS and 67% and 84% for both modalities together. In three cases, IS was doubtful and the final clinical diagnosis was negative for infection. False-positive results were observed in the presence of massive loosening of the prosthesis or in association with metaplastic peri-articular bone formation. In three of the four false-negative results, infection was proven only after enrichment of the culture, and the bacterium was Staphylococcus epidermidis. In 12/33 (36%) positive bone scans IS allowed the diagnosis of infection to be excluded. Overall accuracy of both modalities together was 81% and the negative predictive value was 93%, which compares favourably with the results reported for other non-invasive methods.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 51 条
[1]  
ALAZRAKI N, 1985, J NUCL MED, V26, P711
[2]  
ALAZRAKI NP, 1993, RADIOL CLIN N AM, V31, P783
[3]   CEMENTED TOTAL HIP-PROSTHESIS - RADIOGRAPHIC AND SCINTIGRAPHIC EVALUATION [J].
ALIABADI, P ;
TUMEH, SS ;
WEISSMAN, BN ;
MCNEIL, BJ .
RADIOLOGY, 1989, 173 (01) :203-206
[4]   IMMUNOSCINTIGRAPHIC LOCALIZATION OF INFLAMMATORY LESIONS - CONCEPT, RADIOLABELLING AND INVITRO TESTING OF A GRANULOCYTE SPECIFIC ANTIBODY [J].
ANDRES, RY ;
SCHUBIGER, PA ;
TIEFENAUER, L ;
SEYBOLD, K ;
LOCHER, JT ;
MACH, JP ;
BUCHEGGER, F .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1988, 13 (11) :582-586
[5]   TC-99M-POLYCLONAL IGG AND TC-99M NANOCOLLOID SCANS IN ORTHOPEDICS - A COMPARISON WITH CONVENTIONAL BONE-SCAN [J].
ANG, ES ;
SUNDRAM, FX ;
GOH, ASW ;
AW, SE .
NUCLEAR MEDICINE COMMUNICATIONS, 1993, 14 (06) :419-432
[6]   KINETIC DATA OF INVIVO LABELED GRANULOCYTES IN HUMANS WITH A MURINE TC-99M-LABELED MONOCLONAL-ANTIBODY [J].
BECKER, W ;
BORST, U ;
FISCHBACH, W ;
PASURKA, B ;
SCHAFER, R ;
BORNER, W .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (07) :361-366
[7]  
Bomanji J, 1993, EUR J NUCL MED, V20, P834
[8]   TC-99M-HUMAN IMMUNOGLOBULIN (HIG) - 1ST RESULTS OF A NEW AGENT FOR THE LOCALIZATION OF INFECTION AND INFLAMMATION [J].
BUSCOMBE, JR ;
LUI, D ;
ENSING, G ;
DEJONG, R ;
ELL, PJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (8-10) :649-655
[9]  
CALAME W, 1991, J NUCL MED, V32, P468
[10]   BINDING OF TC-99M-LABELED POLYCLONAL HUMAN-IMMUNOGLOBULIN TO BACTERIA AS A MECHANISM FOR SCINTIGRAPHIC DETECTION OF INFECTION [J].
CALAME, W ;
FEITSMA, HIJ ;
ENSING, GJ ;
ARNDT, JW ;
VANFURTH, R ;
PAUWELS, EKJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1991, 18 (06) :396-400