CHARACTERIZATION OF AN ABSOLUTE CRYOGENIC RADIOMETER AS A STANDARD DETECTOR FOR RADIANT-POWER MEASUREMENTS

被引:47
作者
DATLA, RU [1 ]
STOCK, K [1 ]
PARR, AC [1 ]
HOYT, CC [1 ]
MILLER, PJ [1 ]
FOUKAL, PV [1 ]
机构
[1] CAMBRIDGE RES & INSTRUMENTAT INC,CAMBRIDGE,MA 02139
来源
APPLIED OPTICS | 1992年 / 31卷 / 34期
关键词
RADIANT POWER; ABSOLUTE CRYOGENIC RADIOMETER; RADIOMETRY; ELECTRICAL SUBSTITUTION RADIOMETER; VISIBLE TO LONG-WAVELENGTH IR RADIATION; PHOTODIODE DETECTOR INTERCOMPARISON; LOW-BACKGROUND IR RADIATION;
D O I
10.1364/AO.31.007219
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An active cavity radiometer of the electrical substitution type with a cone receiver that operates at 2-4 K has been developed for measuring radiant fluxes in the dynamic range of 20 nW to 100 muW within an uncertainty of +/-1% (2sigma level). It is a broadband absolute detector with a flat overall absorption efficiency that is > 99% for radiation from the visible to long-wavelength IR. The system is designed based on thermal modeling and experimental measurements of concepts. It has been installed in the cryogenic chamber for low-background infrared radiation calibrations at the National Institute of Standards and Technology (NIST) for testing cryogenic blackbody sources, detectors, and optical components. Its time constant, responsivity, and nonequivalence error have been measured. They are in agreement with design predictions. Radiant power measurements of an amplitude-stabilized He-Ne laser beam with the radiometer and an industry standard photodiode detector, QED-200, have been intercompared and found to be in agreement. The intercomparison ratio of the measurements with the absolute cryogenic radiometer and QED-200 was 1.004 in the 75-100-muW range with an uncertainty of 0.5% (the 3sigma level).
引用
收藏
页码:7219 / 7225
页数:7
相关论文
共 9 条
[1]  
CLARK AF, 1983, MATERIALS LOW TEMPER, P75
[2]  
EBNER SC, 1989, IMAGING INFRARED SCE, V1110, P49
[3]   CRYOGENIC ABSOLUTE RADIOMETERS AS LABORATORY IRRADIANCE STANDARDS, REMOTE-SENSING DETECTORS, AND PYROHELIOMETERS [J].
FOUKAL, PV ;
HOYT, C ;
KOCHLING, H ;
MILLER, P .
APPLIED OPTICS, 1990, 29 (07) :988-993
[4]  
HENGSTBERGER F, 1989, ABSOLUTE RADIOMETRY, P1
[5]  
Parr A. C., 1988, Proceedings of the SPIE - The International Society for Optical Engineering, V940, P26
[6]  
YOKELY CR, 1983, P SOC PHOTO-OPT INS, V416, P2
[7]   SILICON PHOTO-DIODE DEVICE WITH 100-PERCENT EXTERNAL QUANTUM EFFICIENCY [J].
ZALEWSKI, EF ;
DUDA, CR .
APPLIED OPTICS, 1983, 22 (18) :2867-2873
[8]  
PRODUCT LORD CORPORA
[9]  
LASER POWER CONTROLL