AUTOMATED GRADING OF VENOUS BEADING

被引:55
作者
GREGSON, PH [1 ]
SHEN, Z [1 ]
SCOTT, RC [1 ]
KOZOUSEK, V [1 ]
机构
[1] DALHOUSIE UNIV, DEPT OPHTHALMOL, HALIFAX, NS B3H 3J5, CANADA
来源
COMPUTERS AND BIOMEDICAL RESEARCH | 1995年 / 28卷 / 04期
关键词
D O I
10.1006/cbmr.1995.1020
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The degree of venous beading in ocular fundus images has been shown to be a more powerful predictor of conversion to proliferative diabetic retinopathy than any other type of retinal abnormality. Further, the degree of venous beading has been shown to be well correlated with disease progression. An algorithm for automated grading of venous beading in digitized ocular fundus images is described. Thresholding is used to extract a rough silhouette of the vein. Morphological closing is used to fill any holes in the silhouette arising from either the central light reflex or noise. The silhouette is then ''thinned'' to find vein centerlines. Each centerline is partitioned into fixed-length segments of 32 pixels. Vein diameters are measured as a function of distance along each segment with the aid of the local centerline orientations. The resulting diameter data are then interpolated and resampled to generate diameter data at constant sampling intervals. A fast Fourier transform is performed on the resulting data to determine the magnitude spectrum of vein segment diameter. A venous beading index is calculated from the distribution of vein diameter frequency components. Performance of the new algorithm is compared to the currently accepted clinical practice of manual grading in a pilot clinical study of 51 subjects. The algorithm is seen to perform well. (C) 1995 Academic Press, Inc.
引用
收藏
页码:291 / 304
页数:14
相关论文
共 19 条
[1]  
[Anonymous], 1991, OPHTHALMOLOGY, V98, P823
[2]   A METHOD FOR A FULLY-AUTOMATIC DEFINITION OF CORONARY ARTERIAL EDGES FROM CINEANGIOGRAMS [J].
EICHEL, PH ;
DELP, EJ ;
KORAL, K ;
BUDA, AJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :313-320
[3]  
FRANK RN, 1988, RETINAL DISEASES BIO, P141
[4]  
Freeman H., 1974, Computing Surveys, V6, P57, DOI 10.1145/356625.356627
[5]   IMAGE-ANALYSIS USING MATHEMATICAL MORPHOLOGY [J].
HARALICK, RM ;
STERNBERG, SR ;
ZHUANG, XH .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (04) :532-550
[6]   AN IMPROVED PARALLEL THINNING ALGORITHM [J].
HOLT, CM ;
STEWART, A ;
CLINT, M ;
PERROTT, RH .
COMMUNICATIONS OF THE ACM, 1987, 30 (02) :156-160
[7]  
KIM CE, 1984, IEEE T PATTERN ANAL, V6, P372, DOI 10.1109/TPAMI.1984.4767531
[8]  
KOHNER EM, 1984, DIABETOLOGIA, V26, P173
[9]  
KOZOUSEK V, 1992, CAN J OPHTHALMOL, V27, P288
[10]   RECURSIVE TRACKING OF VASCULAR NETWORKS IN ANGIOGRAMS BASED ON THE DETECTION DELETION SCHEME [J].
LIU, IC ;
SUN, Y .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :334-341